B.1.4 performance figures, B.1.4, Table b.5 – Ericsson Multi-Format Receiver RX1290 User Manual
Page 119
![background image](/manuals/84867/119/background.png)
Technical Specification
Description Test
Signal
Limit
K factor K 2T
NTC-7 comp
<1%
Pulse X bar K rating
100 +/- 1%
Frequency Response
(MultiBurst)
FCC Multi-burst
0.5 MHz
1.25 MHz
2 MHz
3 MHz
3.58 MHz
4.1 MHz
0dB +/- 0.2 dB
0dB +/- 0.2 dB
0dB +/- 0.2 dB
0dB +/- 0.2 dB
0dB +/- 0.3 dB
0dB +/- 0.3 dB
Differential Gain
NTC-7 comp
<2%
Differential Phase
NTC-7 comp
<1 Degree
Non-Linearity NTC-7
comp
<5%
Jitter
<5nS
Weighted Luminance Noise
Luminance Ramp
<60 dB
Weighted Luminance Noise
Flat Grey Field
<63 dB
Chrominance PM Noise
Flat Red Field
<55 dB
B.1.4
Performance Figures
Table B.5 HD Analogue Output Specification
Parameter Value
for
Y, R, G, B
Value for
Pb, Pr
Condition Notes
Amplitude
700 mV
± 2%
700 mV
± 2%
100% color bar
DC offset
± 10 mV
± 10 mV
Black field
Bandwidth
DC to 10 MHz
± 0.2 dB
10 MHz to 20 MHz
± 1 dB
20 MHz to 30 MHz
+1 dB/-2.5 dB
DC to 10 MHz
±
0.2 dB
10 MHz to 15 MHz
±
1 dB
Sweep
Group delay
DC to 30 MHz < 50nS
DC to 30 MHz < 50nS
Noise
DC to 30 MHz < -50 dB
DC to 30 MHz < -
50 dB
100% ramp
Out-of-band noise
30 MHz to 100 MHz
< -50 dB
15 MHz to 100 MHz
< -50 dB
Sweep
Linearity
< 5%
< 5%
5 step
EN/LZT 790 0003/2 R1A
B-5