B.1.5 hd sdi, B.1.5, Table b.6 – Ericsson Multi-Format Receiver RX1290 User Manual
Page 120
Technical Specification
Parameter Value
for
Y, R, G, B
Value for
Pb, Pr
Condition Notes
Inter-channel delay < 10 nS
< 10 nS
100% color bar
Interchannel
crosstalk
< -40 dB
< -40 dB
Multiburst
Blanking rise and
fall time
100 nS
± 50 nS
100 nS
± 50 nS
Flat field
20% to 80%
Active line width
inequality
<50 nS
<50 nS
Flat field
Sync edge to start
of active picture
2.586uS +80nS/-0nS
2.586uS +80nS/-0nS
50% to 50%
Sync amplitude
Pos and Neg
300mV
± 5%
300mV
± 5%
Tri-level Sync rise
and fall time
54 nS
± 20 nS
54 nS
± 20 nS
20% to 80%
Output impedance
75
Ω nominal
75
Ω nominal
Return loss
DC to 20 MHz > 20 dB
DC to 20 MHz > 20 dB
Table B.6 Sync Output Specification
Parameter Value
Condition
Notes
H and V Sync.
High Voltage
>2.5V 2.2k Ω
H and V Sync.
Low Voltage
<0.5V 2.2k Ω
B.1.5
HD SDI
HD SDI output supports:
• Embedded
Decoded
Audios
• Closed Captioning (EIA 708B)
• VITC
• VANC
EN/LZT 790 0003/2 R1A
B-6