ProSoft Technology ILX34-MBS485 User Manual
Page 26

Configuration
Page 26 of 34
ProSoft Technology, Inc.
February 18, 2015
The following example shows the module configured as a Master, 19200 baud,
8N1 (8 Data bits, No Parity, and 1 Stop Bit) Framing, RTU mode with a three
second timeout.
Slave Configuration
Label
Description
Type
Set this to “1” for Slave.
Slave ID
1-255. Set this to the desired Slave ID
that the Master is attempting to access.
The Count parameters determine that maximum address that the Master can
access for the ILX34-MBS. The default values represent the max addresses
allowed for the provided Add-On instruction. Valid ranges are: 00001
– 00576,
10001
– 10576, 30001 – 30501 and 40001 – 40501..
Coldboot Bit - If parameters change after initial configuration, use the Coldboot
bit to initiate the changes.