2.1.4 DIP-Switch

The DIP-switch is used to configure operation mode for LLF (Link Lost Forwarding) operation mode for

UTP/Fiber port and relay alarm operation mode. The factory default mode of DIP switch is OFF.

DIP Switch No

Status

Description

ON

Enable Port Alarm. If the port’s link fails, the fault LED will light up.

1

OFF Disable

Port

Alarm

ON

LLF Enable

2

OFF LLF

Disable

ON

100Base-FX Half Duplex mode

3

OFF

100Base-FX Full Duplex mode

ON

100Base-TX Full Duplex mode

4

OFF UTP

Auto-Negotiation

Link Lose Forwarding:

When LLF is enabling, allow UTP link failures to be reported to the fiber side and also allow Fiber link

failure to be reported to the UTP side. Therefore, a link lost forward feature is provided in both UTP and

Fiber side.

#

Notice:

Please don't change the DIP-switch setting when UTP or fiber port is transmitting or receiving data. It

may cause some data error. After change the DIP-switch setting, must execute Power OFF/ON to enable

new configures.

2.1.5 Converter Bottom Panel

The bottom panel of the Converter consist one terminal block connector within two DC power inputs and

one DC IN power jack for extra AC/DC power adapter. Figure 2-2 shows the bottom panel of the switch.

Figure 2-2

IFT-802 Bottom Panel.