4 product specification – PLANET IFT-802 User Manual
Page 5
![background image](https://www.manualsdir.com/files/866041/content/doc005.png)
▫
DIN-Rail or wall mountable
▫
DIP-switches to set the operation mode and Link- Lost-Forwarding function.
Industrial Conformance:
▫
12~48V DC, redundant power with polarity reverse protect function and connective
removable terminal block for master and slave power
▫
0 to 60 Degree C operation temperature
▫ IP-30
Aluminum
case
▫
EMI complies with FCC Class A, CE EN6100-4-2, CE EN6100-4-3, CE EN6100-4-4, CE
EN6100-4-5 and CE EN6100-4-6
▫
Stability testing with IEC60068-2-32(Free fall), IEC60068-2-27(Shock) and
IEC60068-2-6(Vibration)
1.4 Product Specification
Model
IFT-802
Standard
IEEE 802.3 10BASE-T
IEEE 802.3u 100BASE-TX / 100BASE-FX
IEEE 802.3x Flow Control and Back pressure
10/100Mbps TP
CAT-3/5 (10/100Mbps) Twisted Pair cable Auto MDI/MDI-X and Auto-Negotiation
Function Support
Fiber Connector
Multi-Mode SC connector
Architecture
Store and forward
Fiber Parameters
Fiber Core:
Multi-Mode (62.5/125µm, 50/125µm). Wavelength: 1310nm
Fiber Distance:
Multi-Mode Fiber, up to 2Km
Link Lost Forward
TX to Fiber:
If TX port link down, the media converter will force Fiber port to link down
Fiber to TX:
If Fiber port link down, the media converter will force TX port to link down.
DIP Switch
DIP Switch 1:
ON:
Enables Port Alarm
OFF:
Disables Port Alarm
DIP Switch 2:
ON:
Enables LLF (Link Lose Forwarding)
OFF:
Disables LLF (Link Lose Forwarding)
DIP Switch 3:
ON:
100Base-FX Half-mode
OFF:
100Base-FX Full-mode
DIP Switch 4:
ON:
100Base-TX Full-duplex mode
OFF:
Auto-Negotiation
LED
Power (Green), Power1 (Green), Power2 (Green), Fault (Orange)
Fiber:
Link/Activity (Green)
Half/Full Duplex (Orange)