2.2.3. Wall Mount Plate Mounting
To install the Industrial Access Point on the wall, please follow the instructions below.
Step 1: Remove the DIN-Rail from the Industrial Access Point. Use the screwdriver to loose the screws and
remove the DIN-Rail.
Step 2: Place the wall mount plate on the rear panel of the Industrial Access Point.
Figure 2-12
Step 3: Use the screwdriver to screw the wall mount plate on the Industrial Access Point.
Step 4: Use the hook holes at the corners of the wall mount plate to hang the Industrial Access Point.
Step 5: To remove the wall mount plate, reverse the steps above.
2.3. Wiring the Power Input
The 6-contact terminal block connector on the top panel of the Industrial access point is used for two DC
redundant powers input. Please follow the steps below to insert the power wire.
1. Insert positive / negative DC power wires into the contacts 1 and 2 for POWER 1, or 5 and 6 for
POWER 2.