4 wiring the fault alarm contact, Iring the, Ault – PLANET ISW-504PS User Manual
Page 20: Larm, Ontact
User’s Manual
1 2 3 4 5 6
Power 1
Fault
Power 2
- + - +
Figure 2-4:
6-Contacts of Terminal Block Connector
Power Notice:
1. The wire gauge for the terminal block should be in the range between 12 ~ 24 AWG.
2. Performing any of the procedures like inserting the wires or tighten the wire-clamp screws. Ensure
the power is OFF to prevent to get an electric shock.
2.4 Wiring the Fault Alarm Contact
The fault alarm contacts are in the middle (3 & 4) of the terminal block connector as the picture shows below. Inserting the
wires, the Industrial PoE Switch will detect the fault status of the power failure, or port link failure (available for managed
model).
The following illustration shows an application example for wiring the fault alarm contacts
Power Notice:
1. The wire gauge for the terminal block should be in the range between 12 ~ 24 AWG.
2. Performing any of the procedures like inserting the wires or tighten the wire-clamp screws. Ensure
the power is OFF to prevent to get an electric shock.
Insert the wires into the fault alarm contacts
-20 -