beautypg.com

Using the board, Output measurement – Avago Technologies ACPL-339J-000E User Manual

Page 7

background image

7

Using the Board

It is easy to prepare the evaluation board for use. Only minor preparations (just by soldering cables for DC supplies,

proper cables for HVDC+/HVDC

high voltage bus, and load connections) are required. The evaluation board has a

default setup (as shown in Table 2) when it is shipped to the customer. The customer is free to select different settings

for J1, S1 and S2 for his different needs.

Table 2

Recommended PWM frequency V

cc1

V

cc2

w.r.t. Vee

J1

S1

S2

Default Setup

1 kHz to 50 kHz (0 ~ 5 V)

+5Vdc

21.6 V ~ 30 V

Shorted

Shorted

Shorted

J1 is provided to let customer to adjust the DESAT fault detection voltage to 7 V by replacing it with another BYM26E.

S1 jumper is shorted to ground the IN1-. This can be open if differential signal is used across IN1+ & IN1– to drive the LED.

S2 jumper can be shorted when IGBT/Power MOSFET are not connected to Q5 (or Q6) to stop the DESAT fault from occurring. It

has to be open, however, when IGBT/Power MOSFET are connected to activate the DESAT fault protection.

Output Measurement

Figure 5 and Figure 6 show a sample of Input LED and various output waveforms that have been captured. The soft

shutdown waveform are shown clearly in V

gIGBT

waveform.

Figure 5. Input LED (t

ON

< t

MUTE

) and various output voltage waveforms

LED ON

Soft

Shutdown

I

F

V

DESAT

8 V

LED OFF

V

GMOS

V

G(IGBT)

V

OUTN

V

OUTP

FAULT

Ext NMOS OFF

Ext NMOS ON

Ext PMOS OFF

Ext PMOS ON