Table 2. alignment data – Avago Technologies HEDS-8949 User Manual
Page 10

10
Table 2. Alignment data
Vp-p MAX (LOCTEST)
The maximum peak-to-peak voltage for the LOCTEST signal. The amplitude of the signal
will depend on the total stack-up TIR of the code wheel.
1.90
2.00
2.10
2.20
2.30
2.40
2.50
2.60
2.70
2.80
0
45
90
135
180
225
270
315
360
Nominal
V
Duty % AVG
Duty % is calculated on the TiltOut signal with the following formula:
V ( )
SLO
0°
180°
360°
t
T
t
Duty % = x 100%
T
The average value of Duty % is then calculated based on the number of valid TILTOUT
pulses captured.
ON Pulse Width
The ON pulse width of the TiltOut signal, t.
Pulse Ratio
The ratio of periods between pulses generated at TiltOut.
V ( )
SLO
0°
180°
360°
T1
T2
T1
Pulse Ratio =
T2
Results
Provides a PASS / FAIL indicator based on the specification limit provided by the user.
Vp-p