Appendix c: error messages, Start-up error messages, Drive check error messages – Avago Technologies eXtremeRAID 2000 User Manual
Page 49: Appendix c, Extremeraid 2000 error messages
Manual No. DB11-000028-00
C-1
Appendix C
eXtremeRAID 2000
Error Messages
☛
Note
The firmware you are using may have these messages
turned off. However, they are listed here for your
reference.
Start-up Error Messages
The BIOS looks for any initialization message posted by the firmware during
the start-up sequence. If a message is found, one of the following errors
displays on screen and the installation process aborts.
EXR2000 fatal error--Memory test failed!
EXR2000 fatal error--Command interface test failed!
EXR2000 hardware error--Run Diagnostics to pinpoint error
EXR2000 firmware checksum error--Reload firmware
EXR2000 Mismatch between NVRAM & Flash EEPROM
configurations!
Drive Check Error Messages
If mismatches are found, then the BIOS prints out the following:
EXR2000 Configuration Checksum error--Run configuration
utility!
If the firmware detects that during the last power cycle the system was turned
off abruptly leaving some incomplete write operations, the following
message appears:
Recovery from mirror race in progress
WARNING: Dead SCSI devices (Channel Target) : x:y
The following messages may also appear:
EXR2000
cannot recover from Mirror Race!
Some system drives are inconsistent!