beautypg.com

KEPCO RCW 350W Series User Manual

Page 5

background image

RCW350W 120607

3

FIGURE 1 RCW 350W POWER SUPPLY PEAK TO PEAK INPUT SURGE CURRENT FOR T<50µS

Shock:
(non-operating, 1/2 sine pulse, three shocks
on each axis, Power Supply is fixed
on its bottom side)

964.6ft./s

2

(294M/s

2

), 11ms ± 5 msec pulse duration

Input Transient:

The RCW Power Supply (with a 50 ohm termination) should operate trouble free
when a 1us, 2K Volt, 50–60 Hz input is applied between the input and ground ter-
minals.

EMI Conducted:

FCC Class A

Safety:

UL 1950 Recognized, CSA Electrical Bulletin 22.2, No. 234, Level 5 Certified and
EN 60950 (TUV) Approved ,CE marked per Low Voltage Directive (LVD)

Remote Error Sensing:

The RCW 350W Power Supply will compensate up to 0.15 Volts max per load
wire for the RCW 3.3-70K, and up to 0.25 Volts per load wire for the RCW 5-70K,
and up to 0.4 Volts per load wire for all other RCW Models (see Figure 2).

Remote Control ON/OFF:

"High", 2.4V to 24V (or open), unit ON
"Low", 0.0V to 0.4V (or closed), unit OFF- Fan Off
Source current is 1.6mA maximum
The (±)RC terminals are isolated from the AC input terminal and the DC output
terminals. Under normal conditions the (±)RC terminals are high, so when the
function is not used the terminals should be left open.

Power Factor

0.99 typical, satifies EN61000-3-2 Requirements

Dimensions:

4.33 in. (110 mm) x 5.12in. (130 mm) x 8.66 in. (220 mm)

Mounting:

No. M4x8 tapped holes

Maximum Screw Penetration:

0.28 in. (7 mm)

Cooling:

Forced air flow - one fan

Frame Material/Cover Material:

Aluminum

Weight:

5.73lbs. (2.6 Kg)

TABLE 2. POWER SUPPLY RATINGS AND SPECIFICATIONS (CONTINUED)

SPECIFICATION

DESCRIPTION