beautypg.com

0 introduction, 1 scope of manual, 2 description – KEPCO RCW 350W Series User Manual

Page 3: 0 specifications, Table 1. output ratings and specifications, Scope of manual, Description, Specifications, Output ratings and specifications

background image

RCW350W 120607

1

1.0 INTRODUCTION

1.1 SCOPE OF MANUAL

This Operator's Manual covers the installation and operation of the Kepco RCW 350W Series of
Switching Power Supplies. For service information, write directly to: Kepco Inc., 131-38 Sanford Ave-
nue, Flushing, New York, 11355, U.S.A. Please state Model Designation and Serial Number of your
RCW Power Supply. This information can be found on the nameplate of the unit.

1.2 DESCRIPTION

The Kepco RCW 350W Series consists of seven models of Switching Power Supplies, with a single
output as shown in Table 1. RCW power supplies are compliant with the Low Voltage Directive (LVD)
and carry the CE Mark. Units are designed to operate with a universal input voltage within the range of 85
to 264V AC and may be operated with either 100-120V AC, or 200-240V AC (100 to 240 volts nominal
input range), 50-60 Hz (47-66 Hz) input. They will also operate on 125V to 370V dc input. The RCW
350W Series employs a light weight ferrite core transformer with 150 KHz typical switching frequency.
The Power Factor Correction Circuit has a typical switching of 120 KHz. Regulation is provided by
pulse width modulation. A FET power stage, operating in the forward conversion mode provides a
smooth isolated dc output. A resistor and thyristor "soft-start" circuit prevents excessive turn-on current
surge. Overvoltage protection and optically isolated remote TTL ON-OFF control are provided. Current
limiting with automatic recovery from short circuit is featured. Units are enclosed in a wrap-around alu-
minum case with a green LED "output present" light visible on the terminal side of the case.

2.0 SPECIFICATIONS

Table 1 contains specifications and operating limits of individual RCW 350W Series models. Table 2
contains specifications and operating limits common to all RCW 350W Series Models. These specifica-
tions are at nominal input voltages at 25°C unless otherwise specified.

TABLE 1. OUTPUT RATINGS AND SPECIFICATIONS

MODEL RCW 350W

3.3-70K

5-70K

12-30K

15-24K

24-16K

28-13K

48-7.5K

Output Volts d-c

(5)

3.3V

5V

12V

15V

24V

28V 48V

Adjustment Range

(7)

1.8-3.5

3.5-5.5

8.4-13.2

12-16.5

16.5-26.4

25.2-30.8

30.8-52.8

Maximum

Output

Ratings

(A,W)

50°C

amb

Amps

70

70

30

24

16

13

7.5

Watts

245

350

360

360

384

364

360

60°C,

amb

Amps

49

49

21

16.8

11.2

9.1

5.25

Watts

171.5

245

252

252

268.8

254.8

252

70°C,

amb

Amps

28

28

12

9.6

6.4

5.2

3.0

Watts

98

140

144

144

153.6

145.6

144

Current Limit (Amps)

(1)

73-84

73-84

31.5-36

25.2-28.8

16.8-19.2

13.6-15.6

7.8-9.0

OVP Settings (Volts)

(2)

3.96-4.62

6.0-7.0

13.2-15.6

16.5-19.5

26.4-31.2

30.8-36.4

49.44-

59.04

Efficiency

% typical

AC Input 120V

65

72

73

75

76

77

79

AC Input 240V

68

76

77

78

79

80

82

Ripple &
Noise

(3)

(mV, p-p)

source (max)

50

50

70

70

100

100

100

spike noise (max)

(4)

100

100

150

150

200

200

300

Transient

Recovery

(6)

Recovery to 1%
(

1

1

1

1

1

1

1

Excursion ±Vmax

0.5

0.5

0.5

0.5

0.15

0.15

0.15

1)

The Power Supply has a square type overcurrent characteristic, shutdown by undervoltage detection

2)

The Power Supply has a shut-down type (by tracking) overvoltage characteristic. Recovery time to reset 40 seconds minimum

3)

Source component 2x source frequency and switching component approximately 150 KHz, 10 to 100% load and ambient Ta = 25°C

4)

Measure with a 50MHz bandwidth, 10 to 100% load and ambient Tc= 25°C

5)

Output voltage setting = ±1%

6)

A step load change from 50% to 100% of rated load current (with the following tr, tf load changes) produces no more than the output

voltage excursions listed in the above table. tr, tf of load change

:

3.3v and 5v>7µs, 12v>3µs, 15v>2.4µs, 24v>8µs, 28v>6.5µs,

48v>3.5µs, .

7)

Recommended (using internal adjustment pot, par. 3.4). Using external pot (par.3.5) range = 10% to 110% of rated output voltage.