Section 3 - operation, 1 general, 2 ieee 488 (gpib) bus protocol – KEPCO MST 488 Programmer User Manual
Page 27: Table 3-1. ieee 488 (gpib) bus interface functions, General -1, Ieee 488 (gpib) bus protocol -1, Ieee 488 (gpib) bus interface functions -1

MST488-27 013004
3-1
SECTION 3 - OPERATION
3.1
GENERAL
Kepco MST 488-27 Power Module Controller is programmed over a control bus using either
SCPI (Standard Commands for Programmable Instruments) or CIIL (Control Interface Interme-
diate Language) commands. SCPI and CIIL provide a common language used in an automatic
test system.
The control bus can be either the IEEE 488 standard communication bus (General Purpose
Interface Bus, GPIB), or the RS 232C communication bus. (Refer to Table 2-4 for input/output
signal allocations.) Connection of both GPIB and RS 232 ports simultaneously is not recom-
mended.
NOTE: Upon power loss, all programmed values/configurations are lost and must be repro-
grammed.
3.2
IEEE 488 (GPIB) BUS PROTOCOL
Table 3-1 defines the interface capabilities of the MST 488-27 controller (Talker/Listener) rela-
tive to the IEEE 488 (GPIB) bus (reference document ANSI/IEEE Std 488: IEEE Standard Digital
Interface for Programmable Instrumentation) communicating with a Host Computer–Controller
(Talker/Listener).
Tables 3-2 and 3-3 define the messages sent to the MST 488-27, or received by the MST 488-
27, via the IEEE 488 bus in IEEE 488 command mode and IEEE 488 data mode, respectively.
These messages are enabled during the “handshake” cycle, with the MST 488-27 controller
operating as either a Talker or a Listener.
TABLE 3-1. IEEE 488 (GPIB) BUS INTERFACE FUNCTIONS
FUNCTION
SUBSET
SYMBOL
COMMENTS
Source Handshake
SH1
Complete Capability (Interface can receive multiline messages)
Acceptor Handshake
AH1
Complete Capability (Interface can receive multiline messages)
Talker
T6
Basic talker, serial poll, unaddress if MLA (My Listen Address) (one-byte
address)
Listener
L4
Basic listener, unaddress if MTA (My Talk Address) (one-byte address).
Service Request
SR1
Complete Capability. The interface sets the SRQ line true if there is an
enabled service request condition.
Remote/Local
RL2
No Local lock-out.
Parallel Poll
PP0
No Capability
Device Clear
DC1
Complete Capability. DCL (Device Clear) and SDC (Selected Device Clear)
supported.
Device Trigger
DT1
GET supported.
Controller
C0
No Capability