Thermo Pride Gas/Propane Furnace Premiere Series 2-Stage CHX3 User Manual
Page 7

All installations and services must be performed by qualified service personnel.
1
II. FURNACE SPECIFICATIONS
CHX3 SERIES
MODEL NO.
CHX3-75
CHX3-100
CHX3-125
BTU/HR INPUT (High fire/ Low fire)
75,000 / 52,000
100,000 / 70,000 125,000 / 87,500
BTU/HR OUTPUT (High fire/ Low fire)
71,000 / 49,000
95,000 / 66,000
115,000 / 82,000
HEIGHT OF CASING
44-1/4”
44-1/4”
44-1/4”
WIDTH OF CASING
17”
21”
24”
DEPTH OF CASING
27-1/2”
27-1/2”
27-1/2”
WARM AIR OUTLET
15 x 18
19 x 18
22 x 18
RETURN AIR INLET
25 x 16
25 x 16
25 x 16
DIA. OF FLUE
2”
3”
3”
DIA. OF COMBUSTION
AIR INTAKE
2”
3”
3”
CFM from .2” & .5” w.c.
EXTERNAL STATIC PRESSURE
COOLING
COOLING
COOLING
@COOLING TAP A
1000
1200
1400
@COOLING TAP B
800
1000
1200
@COOLING TAP C
1200
1400
1600
@COOLING TAP D
1400
1600
2000
HEATING
HEATING
HEATING
@HEATING TAP A (High fire/Low fire)
931 / 760
1243 / 1015
1556 / 1270
TEMPERATURE RISE
70 / 60
70 / 60
70 / 60
BLOWER MOTOR HP
.5
.75
1
POWER CHOKES
-
2.65 Mh
2.1 Mh
LARGEST RECOMMEDED
AIR CONDITIONER
3.5 Ton
4 Ton
5 Ton
SIZE OF FILTERS
24-3/4” x 15-3/4” 24-3/4” x 15-3/4” 24-3/4” x 19-3/4”
NOTES:
1. BTU output based on annual fuel utilization efficiency rated by manufacturer.
2. On all outlet and inlet dimensions, the first dimension is width.
3. To permit largest recommended air conditioning (at .5 static pressure), selection of the highest motor speed is
required.