beautypg.com

Thermo Pride Gas/Propane Furnace Premiere Series 2-Stage CHX3 User Manual

Page 48

background image

All installations and services must be performed by qualified service personnel.

42

Figure 23:




b. Turn the inner plastic adjustment screw clockwise to increase, or counterclockwise to

decrease, the gas pressure (and gas flow) to the main burner.

c. Replace the regulator cover screw and tighten it firmly to prevent gas leakage.

d. Referring to Table 5, measure the gas pressure and to confirm it has been adjusted to within

the allowable range. Repeat adjustments (a) through (c), as required.

Table 5 Design Gas Pressures for each Furnace Model Series,

Operating Mode, and Type of Fuel.

Fuel Gas Type

Propane

Natural

Operating Mode and
Model Series

High Fire

CHX Low

Fire

CDX Low

Fire

High Fire

CHX Low

Fire

CDX Low

Fire

Normal Manifold
Pressure (in. W.G.)

10.0 ± 0.3 4.8 ± 0.3

5.6 ± 0.3

3.5 ± 0.3

1.8 ± 0.3 2.0 ± 0.3

Maximum Gas Supply
Pressure (in. W.G.)

14.0

14.0

Minimum Gas Supply
Pressure (in. W.G.)

11.0

4.5

13. Adjust the room thermostat so the burner will operate on high fire only.

14. To obtain an accurate manifold gas pressure reading, the main burner must be cycled on and off

several times to stabilize the gas control valve pressure regulator diaphragm.

15. Allow the burner to operate for at least 3 minutes before taking gas pressure readings.

16. Using a pressure gauge, measure the burner manifold gas pressure.

17. If checking the input rate by measuring burner manifold pressure, proceed to step 18. If

measuring the input rate by clocking the gas meter, repeat steps 9 through 11, above.