Installer’s Information Manual

Table 2. Maximum Pipe Length --Non-Direct Vent

ALLOWABLE PIPE LENGTH (feet)

ALTITUDE

FURNACE

PIPE

NUMBER OF SWEEP ELBOWS (SEE NOTE 1)

INPUT

DIA.

1

2

3

4

5

6

7

8

54,000

2"

112

108

104

100

96

92

88

84

72,000

2"

55

51

47

43

39

35

31

27

72,000

3"

150

150

150

150

150

150

150

150

0'-1000'

90,000

2"

36

32

28

24

20

16

-

-

90,000

3"

150

150

150

145

140

135

130

125

108,000

3"

85

80

75

70

65

60

55

50

126,000

3"

55

50

45

40

35

30

25

20

54,000

2"

97

93

90

86

83

80

76

73

72,000

2"

44

40

36

33

30

26

23

19

72,000

3"

150

150

150

150

150

150

150

150

1001'-2000'

90,000

2"

30

26

23

19

16

-

-

-

90,000

3"

140

135

130

125

120

115

110

105

108,000

3"

75

70

65

60

55

50

45

40

126,000

3"

45

40

35

30

25

20

15

-

54,000

2"

84

81

78

74

71

67

64

61

72,000

2"

37

34

30

27

24

21

18

15

72,000

3"

150

150

150

150

150

150

150

150

2001'-3000'

90,000

2"

24

21

18

14

11

-

-

-

90,000

3"

125

120

115

110

105

100

95

90

108,000

3"

50

45

40

35

30

25

20

15

126,000

3"

36

31

26

21

16

11

-

-

54,000

2"

71

68

64

61

58

55

51

48

72,000

2"

30

27

23

20

17

13

72,000

3"

150

150

150

150

150

150

150

150

3001'-4000'

90,000

2"

19

16

12

-

-

-

-

-

90,000

3"

100

95

90

85

80

75

70

65

108,000

3"

37

32

27

22

17

12

-

-

126,000

3"

30

25

20

15

10

-

-

-

126,000

3"

55

50

45

40

35

30

25

20

See Note 2

below.

54,000

2"

57

54

50

47

44

40

36

33

72,000

2"

25

22

19

16

12

-

-

-

72,000

3"

150

150

150

150

150

150

150

150

4001'-5000'

90,000

3"

85

80

75

70

65

60

55

50

108,000

3"

85

80

75

70

65

60

55

50

See Note 2

126,000

3"

55

50

45

40

35

30

25

20

54,000

2"

43

40

37

33

30

27

24

20

72,000

2"

21

18

14

11

-

-

-

-

72,000

3"

150

150

150

150

150

150

150

150

5001'-6000'

90,000

3"

70

65

60

55

50

45

40

35

108,000

3"

85

80

75

70

65

60

55

50

See Note 2

126,000

3"

55

50

45

40

35

30

25

20

54,000

2"

110

106

104

100

96

92

88

84

72,000

2"

50

46

43

40

36

32

29

25

72,000

3"

150

150

150

150

150

150

150

150

6001'-7000'

90,000

3"

150

150

150

145

140

135

130

125

See Note 2

108,000

3"

85

80

75

70

65

60

55

50

126,000

3"

55

50

45

40

35

30

25

20

54,000

2"

97

93

90

86

83

80

76

73

72,000

2"

50

46

43

40

36

32

29

25

72,000

3"

150

150

150

150

150

150

150

150

7001'-8000'

90,000

3"

150

150

150

145

140

135

130

125

See Note 2

108,000

3"

85

80

75

70

65

60

55

50

126,000

3"

53

48

43

38

33

28

23

18

54,000

2"

84

81

78

74

71

67

64

61

72,000

2"

41

38

34

31

28

24

21

17

72,000

3"

150

150

150

150

150

150

150

150

8001'-9000'

90,000

3"

150

150

150

145

140

135

130

125

See Note 2

108,000

3"

70

65

60

55

50

45

40

35

126,000

3"

40

35

30

25

20

15

-

-

54,000

2"

71

68

64

61

58

55

51

48

72,000

2"

35

31

28

25

21

18

15

-

72,000

3"

150

150

150

150

150

150

150

150

9001'-10000'

90,000

3"

150

150

150

145

140

135

130

125

See Note 2

108,000

3"

55

50

45

40

35

30

25

20

126,000

3"

31

26

21

16

11

-

-

-

NOTE 1: The table assumes the use of sweep elbows. If using hard 90

?

elbows, the vent length should be decreased an

additional 3 feet for every elbow used.

NOTE 2: The shaded portions of the table require the high altitude pressure switch in order to operate the furnace at the listed

vent lengths.