Thermo Pride Thermo Pace Downflow/Horizontal Furnace (CSA) User Manual

Page 12

background image

Page 12

Installer’s Information Manual

Table 1. Maximum Pipe Length --Direct Vent

ALLOWABLE PIPE LENGTH (feet of each pipe)

ALTITUDE

FURNACE

PIPE NUMBER OF SWEEP ELBOWS (each pipe) (SEE NOTE 1)

INPUT

DIA.

1

2

3

4

5

6

7

8

54,000

2"

40

40

40

40

40

40

40

40

72,000

2"

40

40

37

33

30

27

23

20

72,000

3"

40

40

40

40

40

40

40

40

0'-1000'

90,000

2"

30

26

22

19

15

11

-

-

90,000

3"

40

40

40

40

40

40

40

40

108,000

3"

40

40

40

40

40

40

40

40

126,000

3"

40

40

40

40

35

30

25

20

54,000

2"

40

40

40

40

40

40

40

40

72,000

2"

40

37

33

29

25

21

19

15

72,000

3"

40

40

40

40

40

40

40

40

1001'-2000'

90,000

2"

25

22

19

16

12

-

-

-

90,000

3"

40

40

40

40

40

40

40

40

108,000

3"

40

40

40

40

40

40

40

40

126,000

3"

40

38

33

28

22

16

11

-

54,000

2"

40

40

40

40

40

40

40

40

72,000

2"

35

33

29

25

21

17

13

-

72,000

3"

40

40

40

40

40

40

40

40

2001'-3000'

90,000

2"

22

19

16

14

-

-

-

-

90,000

3"

40

40

40

40

40

40

40

40

108,000

3"

40

40

40

40

40

40

40

40

126,000

3"

35

30

25

20

15

10

-

-

54,000

2"

40

40

40

40

40

40

40

40

72,000

2"

30

28

26

24

22

20

18

17

72,000

3"

40

40

40

40

40

40

40

40

3001'-4000'

90,000

2"

15

13

11

-

-

-

-

-

90,000

3"

40

40

40

40

40

40

40

40

108,000

3"

40

40

40

40

40

40

40

40

126,000

3"

30

25

20

15

10

-

-

-

126,000

3"

40

40

40

40

35

30

25

20

See Note 2

below.

54,000

2"

40

40

40

40

40

40

40

40

72,000

2"

26

22

17

14

12

-

-

-

72,000

3"

40

40

40

40

40

40

40

40

4001'-5000'

90,000

3"

40

40

40

40

40

40

40

40

108,000

3"

40

40

40

35

30

25

20

15

108,000

3"

40

40

40

40

40

40

40

40

See Note 2

below.

126,000

3"

40

40

40

40

35

30

25

20

54,000

2"

40

40

40

40

40

40

40

40

72,000

2"

21

18

14

11

-

-

-

-

72,000

3"

40

40

40

40

40

40

40

40

5001'-6000'

90,000

3"

40

40

40

40

40

40

40

40

108,000

3"

40

35

30

25

20

15

10

-

108,000

3"

40

40

40

40

40

40

40

40

See Note 2

126,000

3"

40

40

40

40

35

30

25

20

54,000

2"

40

40

40

40

40

40

40

40

72,000

2"

40

40

40

40

36

32

28

24

72,000

3"

40

40

40

40

40

40

40

40

6001'-7000'

90,000

3"

40

40

40

40

40

40

40

40

See Note 2

below.

108,000

3"

40

40

40

40

40

40

40

40

126,000

3"

40

40

40

40

35

30

25

20

54,000

2"

40

40

40

40

40

40

40

40

72,000

2"

40

40

40

37

35

32

28

24

72,000

3"

40

40

40

40

40

40

40

40

7001'-8000'

90,000

3"

40

40

40

40

40

40

40

40

See Note 2

below.

108,000

3"

40

40

40

40

40

40

40

40

126,000

3"

40

40

40

40

35

30

25

20

54,000

2"

40

40

40

40

40

40

40

40

72,000

2"

40

40

37

34

31

28

24

21

72,000

3"

40

40

40

40

40

40

40

40

8001'-9000'

90,000

3"

40

40

40

40

40

40

40

40

See Note 2

below.

108,000

3"

40

40

40

40

40

40

40

40

126,000

3"

40

40

40

35

30

25

20

15

54,000

2"

40

40

40

40

40

40

40

40

72,000

2"

40

37

35

31

27

24

21

18

72,000

3"

40

40

40

40

40

40

40

40

9001'-10000'

90,000

3"

40

40

40

40

40

40

40

40

See Note 2

below.

108,000

3"

40

40

40

40

40

40

40

40

126,000

3"

40

35

30

25

20

15

-

-

NOTE 1: The table assumes the use of sweep elbows. If using hard 90

?

elbows, the vent length should be decreased

anadditional 3 feet for every elbow used.

NOTE 2: The shaded portions of the table require the high altitude pressure switch in order to operate the furnace at the

listed vent lengths.