Mounting and installation – Elation Professional 5R User Manual
Page 17
Platinum Spot 5R™
©Elation Professional, Los Angeles Ca.
17
www.ElationLighting.com
7. MOUNTING AND INSTALLATION
Cautions:
For added protection mount the fixtures in areas outside walking paths, seating areas, or in
areas were the fixture might be reached by unauthorized personal.
Before mounting the fixture to any surface, make sure that the installation area can hold a
minimum point load of 10 times the device’s weight.
Fixture installation must always be secured with a secondary safety attachment, such as an
appropriate safety cable.
Never stand directly below the device when mounting, removing, or servicing the fixture.
Caution!
When install the fixture be sure there is no highly inflammable
material within a distance of 1.5 feet
Mounting
The Platinum Spot 5R™ is fully operational in two different mounting positions, hanging
upside-down from a ceiling, or set on a flat level surface (see illustration on next page). Be
sure this fixture is kept at least 0.5m away from any flammable materials (decoration etc.).
Always use and install the supplied safety cable as a safety measure to prevent accidental
damage and/or injury in the event the clamp fails.
Refer to regulations BGV C1 (formerly VBG 70) and DIN VDE0711-217
for proper installation in Europe To ensure proper installation, only
qualified staff should attempt installation.