RIGOL DG1000 Series User Manual
Page 18
RIGOL
Quick Guide for DG1000
10
Press
to switch the interface to graph mode:
Figure 9 AM setting interface under graph display
Setting method of other waveforms are the same as the
example above. All the parameters permitted to be set are
listed in the following table.
Table 2 Parameters of modulated waveforms
Types
Parameters
AM
Type (AM), SrcInt (Depth, AMFreq, Shape )/
SrcExt
FM
Type (FM), SrcInt (Deviat., FMFreq, Shape )/
SrcExt (Deviat.)
FSK
Type (FSK), SrcInt (HopFreq, FSK Rate)/
SrcExt (HopFreq)
PM
Type (PM), SrcInt (Deviat., PMFreq, Shape )/
SrcExt (Deviat.)
3. Sweep Waveform Settings
In frequency sweep mode, sweep waveforms could be
generated and outputted from the start frequency to the stop
frequency during specified time by CH1 of DG1000. Sine,
Square, Ramp or Arbitrary (without DC) waveform can be used
to generate sweep waveforms, except for pulse and noise.