BUS Zone Parameters: iWISE QUAD Grade 2
Quick Keys
Parameter
Default
Range
[2][0][3][zz] 
[3][1] 
Remote (manual)
The remote self test is performed by the system when a user manually 
selects the Diagnostics option from the Maintenance menu via the ProSYS 
User Functions menu. 
[2][0][3][zz] 
[3][2] 
Local (automatic)
Once an hour, the detector automatically checks that the it's channels are 
functioning properly. 
BUS Zone Parameters: iWISE QUAD Grade 3
Quick Keys
Parameter
Default
Range
[2][0][3][zz][1] LEDS
On
Defines the LEDS operation mode.
[2][0][3][zz][1] 
[1] to [2] 
LEDS Options
1) Off - Disables the LEDS operation. 
2) On – Enables the LEDS operation. 
[2][0][3][zz][2] Sensitivity
Normal
Defines the sensitivity of the detector (PIR).
[2][0][3][zz][2] 
[1]to[4] 
Sensitivity Options
1) Low 2) High
[2][0][3][zz][3] Anti-Mask
Enable
Defines the operation of Anti Masking detection.
[2][0][3][zz][3] 
[1]to[2] 
Anti-Mask Options
1) Disable 2) Enable and behaves according to the settings defined in quick 
keys [2][0][3][zz][4]. 
[2][0][3][zz][4] Set/Unset
No
Defines the operation of the anti masking feature while the detector is set or 
unset.
[2][0][3][zz][4] 
[1]to[2] 
Set/Unset Options
1) No – When detector is set or unset Anti-mask behaves according to the 
settings defined in quick keys [2][0][3][zz][6] above. 
2) Yes – when detector is set Anti-mask is disabled. When detector is unset 
Anti-mask behaves according to the settings defined in quick keys 
[2][0][3][zz][3]
[2][0][3][zz][5] Self Test
Remote
Used to test the detection technologies. In the event of a failed test, a Self 
Test Fault is created. 