RISCO Group ProSYS Version 8.xx User Manual
Page 6

6
ProSYS Version 8.xx - Supplementary Instructions
BUS Zone Parameters: iWISE DT Grade 2
Quick Keys
Parameter
Default
Range
[2][0][3][zz]
[1]
LEDS
On
Defines the LEDS operation mode.
[2][0][3][zz]
[1] [1] to [2]
LEDS Options
1) Off - Disables the LEDS operation.
2) On – Enables the LEDS operation.
[2][0][3][zz]
[2]
MW (Microwave) Range
Trimmer
Defines the microwave channel range.
[2][0][3][zz]
[2] [1] to [7]
MW Range Options
1) Minimum 2) 25% 3) 50% 4) 65% 5) 85% 6) Maximum 7) Trimmer (MW is
defined by the trimmer setting on the PCB)
[2][0][3][zz]
[3]
ACT
No
Defines the Anti-Cloak™ Technology (ACT) operation mode.
[2][0][3][zz]
[3] [1] to [2]
ACT Options
1) No - Disables the ACT mode.
2) Yes – Enables the ACT mode.
[2][0][3][zz]
[4]
Automatic Microwave Omit
No
Defines whether the MW channel will be bypassed or not while the detector
identifies trouble in the MW channel.
[2][0][3][zz]
[4] [1] to [2]
Automatic Microwave Omit
Options
1) No - While detecting a problem in the MW channel it is not omitted. Alarm
condition cannot be established until the MW channel is fixed.
2) Yes - Switches the detector to operate only in PIR mode in case of MW
trouble.
[2][0][3][zz]
[5]
Green Line
No
A feature that follows environmental guidelines by avoiding surplus emission.
This feature defines the activation of the microwave channel while the system
is disarmed.
[2][0][3][zz]
[5] [1] to [2]
Green Line Options
1) No - Green Line feature is disabled. MW is constantly activated.
2) Yes – Green Line feature is activated.
[2][0][3][zz]
[6]
Self Test
Remote
Used to test the detection technologies. In the event of a failed test, a Self
Test Trouble is created.
[2][0][3][zz]
[6][1]
Remote (manual)
The remote self test is performed by the system when a user manually
selects the Diagnostics option from the Maintenance menu via the ProSYS
User Functions menu.