RISCO Group ProSYS Version 8.xx User Manual
Page 6

6
ProSYS Version 8.xx - Supplementary Instructions
BUS Zone Parameters: iWISE DT Grade 2
Quick Keys
Parameter
Default
Range
[2][0][3][zz] 
[1] 
LEDS
On
Defines the LEDS operation mode.
[2][0][3][zz] 
[1] [1] to [2] 
LEDS Options
1) Off - Disables the LEDS operation. 
2) On – Enables the LEDS operation. 
[2][0][3][zz] 
[2] 
MW (Microwave) Range
Trimmer
Defines the microwave channel range.
[2][0][3][zz] 
[2] [1] to [7] 
MW Range Options
1) Minimum 2) 25% 3) 50% 4) 65% 5) 85% 6) Maximum 7) Trimmer (MW is 
defined by the trimmer setting on the PCB) 
[2][0][3][zz] 
[3] 
ACT
No
Defines the Anti-Cloak™ Technology (ACT) operation mode.
[2][0][3][zz] 
[3] [1] to [2] 
ACT Options
1) No - Disables the ACT mode. 
2) Yes – Enables the ACT mode. 
[2][0][3][zz] 
[4] 
Automatic Microwave Omit
No
Defines whether the MW channel will be bypassed or not while the detector 
identifies trouble in the MW channel. 
[2][0][3][zz] 
[4] [1] to [2] 
Automatic Microwave Omit
Options
1) No - While detecting a problem in the MW channel it is not omitted. Alarm 
condition cannot be established until the MW channel is fixed.
2) Yes - Switches the detector to operate only in PIR mode in case of MW 
trouble.
[2][0][3][zz] 
[5] 
Green Line
No
A feature that follows environmental guidelines by avoiding surplus emission. 
This feature defines the activation of the microwave channel while the system 
is disarmed.
[2][0][3][zz] 
[5] [1] to [2] 
Green Line Options
1) No - Green Line feature is disabled. MW is constantly activated. 
2) Yes – Green Line feature is activated.
[2][0][3][zz] 
[6] 
Self Test
Remote
Used to test the detection technologies. In the event of a failed test, a Self 
Test Trouble is created. 
[2][0][3][zz] 
[6][1] 
Remote (manual)
The remote self test is performed by the system when a user manually 
selects the Diagnostics option from the Maintenance menu via the ProSYS 
User Functions menu. 