beautypg.com

RISCO Group Orbit RP200VC User Manual

Voice module, General description, Voice module features

background image

© RISCO Group 06/2011 5IN200VC D

VOICE MODULE

INSTALLATION INSTRUCTIONS

RP200VC

(For use on and

Control Panels)

UK

Tel: 44-(0)-161-655-5500

E-mail: [email protected]
ITALY

Tel: +39-02-66590054

E-mail: [email protected]
SPAIN

Tel: +34-91-490-2133

E-mail: [email protected]
FRANCE

Tel: +33-164-73-28-50

E-mail: [email protected]
BELGIUM

Tel: +32-2522-7622

E-mail: [email protected]
U.S.A

Tel: +1-631-719-4400

E-mail: [email protected]
BRAZIL

Tel: +55-11-3661-8767

E-mail: [email protected]
CHINA (Shanghai)

Tel: +86-21-52-39-0066

E-mail: [email protected]
CHINA (Shenzhen)

Tel: +86-755-82789285

E-mail: [email protected]
POLAND

Tel: +48-22-500-28-40

E-mail: [email protected]
ISRAEL

Tel: +972-3-963-7777

E-mail: [email protected]

RISCO Group Contacting Info

RISCO Group is committed to customer service and

product support.

You can contact us through our

web site (www.riscogroup.com) or at the following

telephone and fax numbers:

GENERAL DESCRIPTION:

The Voice Module is a unique service component, which

enables you to record up to three short messages that

replace the alarm tones normally produced in the

Follow-Me mode. The messages are sent to any of the

pre-programmed phone numbers, informing its owner that

there has been a particular alarm at a specific location.

The messages are triggered by utility outputs, which work

in unison with the Follow-Me function.

VOICE MODULE FEATURES:

- 3 different voice messages can be recorded on three

different channels, up to a total of 64 seconds.
- Message 1, 2 and message 3 are about 20 seconds long.
- Operates together with the Follow-Me feature.
- Messages are triggered by utility output (UO) from the

panel or it’s Utility Output Expansion board.
- The message will keep on playing until the Follow-Me

mode hangs up or the siren times out.
- It can be connected to the new version of the Orbit-Pro

and Orbit-6 panels.
- It can be connected to a local speaker for play back.
- Alarm report will be first sent to the monitoring station, if

selected, before sending voice message in the Follow-Me

mode.

MOUNTING:

The Voice Module should be mounted inside the metal

cabinet near the control panel. Insert one side of the

module between the tracks on the bottom of the metal

cabinet.

Use four screws (supplied) to mount the panel inside the

holes in the bracket.

PC BOARD ADJUSTMENTS:

ENABLE VOICE JUMPER:

Enable voice
When recording a message, testing a message or

using a single message.

Disable voice
When using more than a single message.

PLAY / REC. JUMPER:

Record
To record a message place the jumper onto both pins.

Play
To enable message transmission or to check

messages, remove the jumper and place it on one pin.

SIG OUT TERMINAL:

Enables the transfer of the audio signal from the Voice

Module to the main panel.

ENABLE TERMINAL (LABELED IN):

Then more than a single message is required, the

ENABLE terminal should be connected to UO1 and

programmed as “Voice Module Enable”. This connection

allows the voice messages and the Follow-Me function to

stay synchronized.

VOICE COAXIAL CABLE:

Use the supplied coaxial cable to transfer the audio signals

from Voice Module to the main panel.

The wiring of the cable should be as follows:
1. Orbit panel: Connect the plug of the cable to the SIG IN

pins and the black wire to the COM of one of the zones.
2. Voice Module: Connect the twisted-shield wire to the

COM (-) and the white wire to the SIG OUT terminal.

Recording a message:

To record messages please use the following instructions:
1. Place the ENABLE jumper onto both pins.
2. Place the PLAY / REC jumper onto both pins.
3. In order to record message No.1 hold down MSG1

(Message 1) and talk to the microphone from a distance

of 10-15 cm. The LED will turn on while pushing the

button.
4. Release the button when finished talking. Repeat stage

3 to record message No.2 and message No.3.

Play-back:

Carried out in order to check the quality of the messages

you have recorded are to your satisfaction.
1. Place the ENABLE jumper onto both pins.
2. Remove the PLAY / REC jumper and place it on one

pin.
3. Connect a speaker to the speaker’s terminals. Pay

attention to the right polarity.
4. In order to listen to message No.1 push MSG1 button

shortly. The LED will turn on while pushing the button.

In case of pushing the button continuously, the message

will be played circulatory as long as you hold the button.
5. Repeat stage 3 to listen to messages 2 and 3.

NOTE:

The speaker must be disconnected after completing
the preparation of the Voice Module.

Erasing a message:

By recording a new message, the old message will be

automatically erased. To record new messages go to

recording messages instructions.

INSTALLATION:

The Voice Module is triggered by a pre-programmed utility

output and activated in unison with the Follow-Me function.

Be sure to enter the actual Follow-Me telephone number in

the user function to enabe the dialing and use of the

Follow-Me feature.The Voice module can be connected in

two different ways.

The following ia a step by step procedure for proper

installation of the Voice Module. Please read the

instructions carefully before proceeding.

NOTE:

When connecting to Orbit-6 make sure to define
“Voice Module” as

YES in location 26.

All the connection figures refer to Orbit-6 panel but
the wiring instructions are the same for the
connection to the Orbit-Pro panel.

OPTION NO.1:

Using a single message:

This option is recommented only if one voice message is

needed. In this configuration the voice message will keep

playing once an alarm has occured and a Follow-Me

number has been defined. The Follow-Me mode activates

the voice messages.

The UO deactivates after the Follow-Me period termina-

tion.

Wiring instructions:

1. Place the ENABLE jumper onto both pins.
2. Remove the PLAY / REC jumper and place it on one

pin, the one near the PLAY label. (After a message has

been recorded).
3. Connect the first 2 terminals, marked as AUX (+) and

COM (-) to the corresponding terminals on the main

board of the Orbit-Pro or Orbit-6.
4. Voice Module coaxial cable wiring: Please refer to the

wiring explanation of the “Voice Coaxial Cable” section.

Remember: The SIG IN pins are located only on the
Orbit-Pro new version panel and the Orbit-6.

5. Optional: Connect the speaker to the speaker’s

terminals. Pay attention to the polarity. (Remove when

done).
6. The EN terminal stays free.
7. Connect the UO / EOL terminal on the main board to

one of the message terminals on the Voice Module

panel (MSG1, MSG2, MSG3), depending on the

message required to be sent out (See figure 1).

NOTE:

The Orbit-Pro and Orbit-6 have one 70 mA transistor
output on the main board which provides a negative trip.
8. When using UO expander, connect one of the message

terminals on the Voice Module panel (MSG1, MSG2,

MSG3), depending on the message required to be sent

out, to one of the terminals of the desired UO (See

figure 2).
9. Connect the second terminal of the UO to COM (-).