RISCO Group ProSYS Version 8.xx User Manual
Page 8

8
ProSYS Version 8.xx - Supplementary Instructions
BUS Zone Parameters: iWISE DT Grade 3
Quick Keys
Parameter
Default
Range
[2][0][3][zz][6] 
[1] to [2] 
Anti-Mask Options
1) Disable 2) Enable and behaves according to the settings defined in quick 
keys [2][0][3][zz][7]. 
[2][0][3][zz][7] Set/Unset
No
Defines the operation of the anti masking feature while the detector is set or 
unset.
[2][0][3][zz][7] 
[1] 
Set/Unset Options
1) No – When detector is set or unset Anti-mask behaves according to the 
settings defined in quick keys [2][0][3][zz][6] above. 
2) Yes – when detector is set Anti-mask is disabled. When detector is unset 
Anti-mask behaves according to the settings defined in quick keys 
[2][0][3][zz][6]
[2][0][3][zz][8] Self Test
Remote
Used to test the detection technologies. In the event of a failed test, a Self 
Test Fault is created. 
[2][0][3][zz][8] 
[1] 
Remote (manual)
The remote self test is performed by the system when a user manually 
selects the Diagnostics option from the Maintenance menu via the ProSYS 
User Functions menu. 
[2][0][3][zz][8] 
[2] 
Local (automatic)
Once an hour, the detector automatically checks that the detector’s channels 
are functioning properly. 
BUS Zone Parameters: iWISE QUAD Grade 2
Quick Keys
Parameter
Default
Range
[2][0][3][zz] 
[1] 
LEDS
On
Defines the LEDS operation mode.
[2][0][3][zz] 
[1] [1] to [2] 
LEDS Options
1) Off - Disables the LEDS operation. 
2) On – Enables the LEDS operation. 
[2][0][3][zz] 
[2] 
Sensitivity
Normal
Defines the sensitivity of the detector (PIR).
[2][0][3][zz] 
[2] [1]to[4] 
Sensitivity Options
1) Low 2) High
[2][0][3][zz] 
[3] 
Self Test
Remote
Used to test the detection technologies. In the event of a failed test, a Self 
Test Trouble is created. 