RISCO Group ProSYS Version 8.xx User Manual
Page 5

ProSYS Version 8.xx - Supplementary Instructions
5
d.
Press
to confirm.
e.
Repeat the above steps for other BUS detectors.
2. Assign the iWISE BUS detectors to a Zone:
a.
From the main Engineer menu select [2] Zones > [1] One by One.
b.
Select the zone number that you want to assign the BUS detector.
Note:
If you defined a virtual BUS Zone Expander, select a zone number from the virtual zones (defined
by the BUS Zone expander).
c.
Define Partitions, Groups, Zone Type and Zone Sound.
d.
In the Termination category, select [5] BUS Zone followed by
.
e.
Select the BUS zone number to assign to the programmed zone. The type field
will be updated automatically when selecting the zone.
f.
Press
. The loop response category is not applicable to a BUS zone.
g.
Press
, assign a label and press
.
3. If you want to use the extra wired zone input on the iWISE BUS detector:
a.
Repeat steps a. – c. in step 2 above.
b.
In the Termination category, select the relevant BUS Zone input termination:
[07] BUS Zone Input N/C
[08] BUS Zone Input EOL
[09] BUS Zone Input DEOL
[10] BUS Zone Input N/O
[11] BUS Zone Input TEOL
c.
Press
. Select the BUS zone that the input zone belongs to. The Type field
will be updated automatically when selecting the zone.
d.
Press
. Define the loop response time.
e.
Press
, assign a label and press
.
4. Configure the iWISE BUS detector parameters:
a.
From the main Engineer menu select [2] Zones > [0] Miscellaneous > [3] BUS
Zone Parameters.
b.
Select the zone that the BUS Zone was assigned to and press
.
c.
Use the following tables to configure the parameters for the relevant iWISE BUS
detector.