beautypg.com

Empty run test data – Electrolux FOM 71 CLS User Manual

Page 85

background image

24:3

Table 1

FOM 71 MP-Lab

Estimated/
defined std
values

Estimated/
defined std
ranges

RRT2008
Average
value

Measured
value

16 IEC/CENELEC(Not Com-
pulsory)
IEC 60456 Cotton 60 Empty
run
Time:
Total program time

Min,sec

78:00

2:00

78:24

Heating time cold - 20ºC

Min,sec

1,00

0:30

0:54

Heating time 20ºC - 40ºC

Min,sec

7:30

0:30

7:19

Heating time 40ºC - 60ºC

Min,sec

8:15

0:30

8:25

Total mainwash time

Min,sec

52:45

1:30

52:47

Filling time of water first fill

Min,sec

1:45

0:15

1:43

Temperature:
Cold water inlet tempera-
ture

ºC

15.0

2.0

15.3

At end of heating to 40 ºC.

ºC

40.0

1,0

40.1

At end of heating to 60 ºC

ºC

60.0

1,0

60.3

At the end of mainwash

ºC

55,0

2.0

56.2

Water:
Amount of water in main-
wash

Litre

26.0

0,5

26.0

Amount of water in rinse 1

Litre

18,0

0,5

18.0

Amount of water in rinse 2

Litre

18,0

0,5

18.1

Amount of water in rinse 3

Litre

18,0

0,5

18.1

Amount of water in rinse 4

Litre

18,0

0,5

18.1

Total amount

Litre

98.0

2.5

98.2

Energy:
Total energy consumption

kWh

1,800

0,150

1.830

Voltage:
Line voltage during the test

V

230

4

231

Ambient temperature:
Room temperature close to
machine

ºC

23.0

2

23.2

Empty run test data