Empty run test data – Electrolux FOM 71 CLS User Manual
Page 85
24:3
Table 1
FOM 71 MP-Lab
Estimated/
defined std
values
Estimated/
defined std
ranges
RRT2008
Average
value
Measured
value
16 IEC/CENELEC(Not Com-
pulsory)
IEC 60456 Cotton 60 Empty
run
Time:
Total program time
Min,sec
78:00
2:00
78:24
Heating time cold - 20ºC
Min,sec
1,00
0:30
0:54
Heating time 20ºC - 40ºC
Min,sec
7:30
0:30
7:19
Heating time 40ºC - 60ºC
Min,sec
8:15
0:30
8:25
Total mainwash time
Min,sec
52:45
1:30
52:47
Filling time of water first fill
Min,sec
1:45
0:15
1:43
Temperature:
Cold water inlet tempera-
ture
ºC
15.0
2.0
15.3
At end of heating to 40 ºC.
ºC
40.0
1,0
40.1
At end of heating to 60 ºC
ºC
60.0
1,0
60.3
At the end of mainwash
ºC
55,0
2.0
56.2
Water:
Amount of water in main-
wash
Litre
26.0
0,5
26.0
Amount of water in rinse 1
Litre
18,0
0,5
18.0
Amount of water in rinse 2
Litre
18,0
0,5
18.1
Amount of water in rinse 3
Litre
18,0
0,5
18.1
Amount of water in rinse 4
Litre
18,0
0,5
18.1
Total amount
Litre
98.0
2.5
98.2
Energy:
Total energy consumption
kWh
1,800
0,150
1.830
Voltage:
Line voltage during the test
V
230
4
231
Ambient temperature:
Room temperature close to
machine
ºC
23.0
2
23.2
Empty run test data