Calibration of level control system – Electrolux FOM 71 CLS User Manual
Page 17

4:5
Calibration of level control system
5
• Close the door.
• Go down to ”Calibration of level sensor”.
• Press ”Select”.
• Press ”Open” to fill the machine with water until the level reaches the botton
of the inner drum where the ruler is placed.
• Press ”OK”.
• Enter the value read on the ruler in RU units (The first setting is 0=level in
drum.
• Press ”OK”.
• Press ”Open” to fill more water.
• Press ”OK”.
• Enter the value read on the ruler in RU units. (If you enter an incorrect value,
press ”CLR”. Enter new value.
• Press ”OK”.
• Enter another three values, making five in total.
• Once all values have been entered, press ”Save”.
LEVEL CALIBRATION
FILL WATER TO
DESIRED LEVEL
LEVEL:
0 SCU
OPEN
OK