Installation inspection of the reference machine – Electrolux FOM 71 CLS User Manual
Page 11

3:1
Installation inspection of the reference machine
5710 A
1
Wascator FOM 71 CLS
Installation inspection of the
reference machine
Before carrying out any major test series inspect
the installation and check the following terms:
• The machine must be installed on a level
base. The following clearances are recom-
mended in order to facilitate calibration:
At least 500 mm between the machine and
the wall behind and min. 50 mm on both
sides of the machine whether installed next to
the wall or other machines.
• Check the levelling of the machine. The verti-
cal difference from corner to corner of the top
lid shall not exceed 5 mm. If not adjust the
feet of the machine.
• The machine shall be connected using the
supplied Y hose or using two single hoses.
• The water hose and power cable must hang
freely between the machine and wall in order
to prevent disrupting the reference machine
scale system.
• Make sure that the drain installation is made
according to the information on next page.
Observe the required air gap in the drain sys-
tem.
50 mm
500 mm
1