2-INSTALLATION INSTRUCTIONS

Technical Dept. - All rights reserved - Reproduction is prohibited

POSITIONING AND RESTRICTIONS

In the case of simultaneous installation with other heating appliances, provide appropriate air inlets for each one (according to the

instructions of each product).

The product cannot be installed (except for sealed or closed operation appliances with external ducted combustion

air intake):

• in bedrooms or bathrooms;

• in rooms where there are liquid fuel appliances with continuous or intermittent operation that draw the

combustion air from the room they are installed in;

• in rooms where there are B-type gas heating appliances, with or without domestic hot water production and

interconnecting rooms;

• where another heating appliance is installed without an independent air flow.

It is forbidden to place the product in an explosive atmosphere.

MINIMUM DISTANCES

VIVO 80 PELLET

Non-flammable walls

Flammable walls

Comfort Air Version

A = 20 mm

B = 20 mm

A = 50 mm

B = 50 mm

If particularly delicate objects are present, such as furniture, curtains or sofas the distance of the product must be significantly increased.

If the floor is made of wood, it is recommended to place a floor protection in accordance with the Standards in force

in the country of installation.

Heat-sensitive or flammable objects cannot be placed near the product. Keep such objects at a minimum distance of

80 cm from the outermost point of the product.