Safety devices and alarms – MCZ Vivo 80 Pellet Comfort Air - 2012 User Manual
Page 40
38
7-SAFETY DEVICES AND ALARMS
SAFETY DEVICES
The product is supplied with the following safety devices:
SMOKE TEMPERATURE PROBE
Detects the temperature of the smoke, thereby enabling start-up or stopping the product when the temperature drops below the preset
value.
PELLET HOPPER SAFETY THERMOSTAT
If the temperature exceeds the preset safety value, it immediately stops the product, which must cool down before being restarted.
Selector “D” must be set to “Off” for the product to be restored.
ELECTRICAL SAFETY
The product is protected against sudden changes in current by a main fuse in the power supply panel on the rear part of the product. Other
fuses that protect the electronic boards are found on the latter.
SMOKE FAN FAULT
If the fan stops, the electronic board promptly blocks the supply of pellets and the alarm is displayed.
GEAR MOTOR FAULT
If the gear motor stops, the product continues to work until the minimum cool level is reached.
TEMPORARY POWER CUT
If a power cut occurs during operation, the product automatically sets itself in cooling mode when the power is restored and then restarts.
FAILED START-UP
If no flame is developed during start-up, the product will go into alarm status.
IT IS FORBIDDEN TO TAMPER WITH THE SAFETY DEVICES.
The product can be started-up and the automatic function of the probe restored only after having eliminated the cause that
triggered the safety system. This manual will help you understand which anomaly has occurred, and explain how to intervene
according to the alarm message displayed on the product.