9-PROBLEMS/CAUSES/SOLUTIONS

Technical Dept. - All rights reserved - Reproduction is prohibited

ANOMALY

POSSIBLE CAUSES

SOLUTIONS

The product works for a few minutes

and then switches off.

Start-up phase is not completed.

Repeat start-up.

Temporary power cut.

Wait for the automatic restart.

Clogged smoke duct.

Clean the smoke duct.

Faulty or malfunctioning temperature

probes.

Check and replace the probes.

Faulty spark plug.

Check the spark plug and replace it, if

necessary.

Pellets accumulate in the brazier, the

glass of the door gets dirty and the

flame is weak.

Insufficient combustion air.

Make sure there is an air inlet in the room

and it is not clogged. Check that the

combustion air filter on the Ø 5 cm air inlet

pipe is not clogged. Clean the brazier and

check that all the holes are clear. Perform

a general cleaning of the combustion

chamber and the smoke duct. Check the

state of the door gaskets.

Damp or unsuitable pellets.

Change the type of pellets.

Faulty smoke evacuation motor.

Check the motor and replace it, if necessary.

The smoke evacuation motor does

not work.

The product is not powered.

Check the mains current and the

protection fuse.

The motor is faulty.

Check the motor and capacitor and replace

them, if necessary.

The electronic board is faulty.

Replace the electronic board.

The control panel is faulty.

Replace the control panel.

The convection air fan never stops.

Faulty or malfunctioning temperature

control probe.

Check the probe and replace it, if necessary.

Faulty fan.

Check the fan and replace it, if necessary.

The remote control does not work.

The remote control battery is flat.

Replace the batteries.

Faulty remote control.

Replace the remote control.