15-CLEANING

The exchanger can now be lifted and the walls of the hearth can be scraped with a stiff rod or a bottle brush, so that the dirt

falls into the lower compartment.

CAUTION:

the exchanger must be cleaned at the end of the season by an authorised and qualified technician so that any worn

seals may be replaced.

CLEANING THE SMOKE DUCT AND GENERAL CHECKS

Clean the smoke extractor duct, especially around the "T" joints, bends and any horizontal sections.

For information on cleaning the flue, contact a chimney sweep.

Check the seal of the ceramic fibre gaskets on the door of the stove. If necessary, order new replacement seals from the retailer or contact

an authorized service centre to carry out this task.

CAUTION:

The frequency with which the smoke outlet system is cleaned depends on the use of the boiler and the type of

installation.

We recommend relying on an authorised service centre for end-of-season cleaning and maintenance, as they will

carry out all of the previously mentioned work and inspect the stove components.