beautypg.com

Installation and operation, cont’d, Tp receivers • installation and operation, Figure 2-11 — pair skew equalization – Extron electronic TP Receivers User Manual

Page 30: Tp t 15hd a tp r bnc a

background image

TP Receivers • Installation and Operation

Installation and Operation, cont’d

2-18

Skew exists between pairs when the physical length of one

wire pair is different from another. As the transmission cable

length increases, the amount of skew increases. Skew affects

the displayed image when the differential length between wire

pairs exceeds 2 feet, causing the timing of red, green, and blue

video signals to appear out of alignment (horizontal registration

errors). A white vertical line on a black field can appear as

individual red, green, and blue lines that are close together;

the signal transmitted on the shortest wire pair leads the other

colors and appears to the left on the display.
UTP cable test equipment measures and reports wire pair

length. The report on the various pair lengths can be used in

equalizing pair skew. The nominal velocity of propagation

(NVP — the speed at which the signal travels on the

transmission line, measured as a percentage of the speed of

light) of TP cable is very close to that of conventional coaxial

cable. The similarity in NVP means that an additional length

of coax equal to the length of pair skew, placed on the receiver

output, equalizes the effects of pair skew (figure 2-11).
If UTP cable test measurement cannot be done, pair skew can

still be equalized by viewing a test pattern with a critical eye.

Examine the test pattern for loss of horizontal registration and,

through a process of trial and error, equalize any pair skew with

coax extensions on the red, green, and/or blue outputs.

TP T 15HD A

TP R BNC A

TP T

15H

D A

H-S

HIFT

BUF

FER

ED

COM

PUT

ER

INPU

T

AUD

IO

ID

P

IN

4

ID

P

IN

1

1

LOC

AL M

ONIT

OR

PC Computer

CAT 5 UTP Cable

Audio

LCD Projector

...

THEN insert a four foot

extension cable to equalize

TP skew for red video.

IF cable measurement
indicates that the pair
with wires

1 and 2 is

four feet shorter than
the other pairs...

RG

B IN

PU

T

RGB

OUTPUT

R

G

B

H/HV

V

A

AU

DIO

L

R

B

SOG

C SYN

C

PO

WE

R

15V

.5A

DC

L

R

Pair RGB video

1, 2 Red

4, 5 Green
7, 8 Blue

Figure 2-11 — Pair skew equalization