Emerson COPELAND SCROLL SZO22 User Manual
Page 30
24
2008SSD-34 (5/11)
Single-Compressor Module
Maintenance
6.0 s
peCifiCatioNs
Table 7
Compressor Module Specifications
General Information
Inlet pressure range
Model specific - refer to application envelope
Outlet pressure range
70 to 275 psig (depends on model—see page
iv)
Mechanical Description
Module weight
Approximately 350 lb. (160kg)
Suction connection
1.0” NPT
Discharge connection
0.75” NPT
Sound level
Approximately 72 dBA @ 1 m, 58 dBA @ 10 m
Vibration
3 mil at 60 Hz
Minimum cold start ambient temperature
1,4
Compressor -20°F (-29°C) VFD power 14°F (-10°C)
Ambient operating temperature range
1,4
0 to 122°F (-18 to 50°C)
Module dimensions
See
Figure 4 on page 7
Materials of Construction
Compressor - general
Cold rolled steel, aluminum, cast iron as required
Compressor bearings
Self-lubricated, sleeve type, steel backed
Oil heat exchanger
Aluminum
Oil/gas separator tank
Cold rolled steel
Tubes/fittings/skid structure
Stainless/carbon steel
Lubrication
Oil type
Synthetic, 15 or 32 weight, PAO (special factory-supplied blend)
System oil capacity, oz. (ml)
170 fluid ounces (5.0 liters)
Projected oil consumption
2
Approximately 40 oz. (0.9 l) / 8,000 hours at 0.25 psig suction (<5 ppm)
System Electrical (Standard)
Minimum VFD ambient startup temperature
3,4
+14°F (-10°C)
Power supply to inverter
• Voltage range
• Input frequency range
380 to 480VAC (50/60 Hz)
Overpressure detection (outlet)
215 psig open
Underpressure detection (inlet)
0.75 psig open (low pressure system) / 2" water column
Oil overtemperature detection
240°F (110°C) open (280°F for SZV) model specific
Fault output to customer
Packager to establish
Run input from customer
Dry contact
Gas Medium
Natural gas
H
2
S maximum content
5
25 ppm
Moisture content
5
100% saturated, no free liquids
Inlet temperature
5
-20 to 115°F (-28 to 46°C); protection from freezing if water is present
1. If the Compressors are started at temperatures above the listed minimums and continue to run, the minimum operating temperature
is 20°F (-29°C).
2. Based on sweet gas wellhead gas. Results may vary due to gas quality and site conditions.
3. Do not apply power to the VFD if ambient temperature is below this level.
4. If power is continuously supplied to the VFD when the Compressor is off, the minimum starting temperature is -4°F (-20°C).
5. Consult factory for more details and applications guidelines.