beautypg.com

2 platform symptoms diagnosis – Emerson COPELAND SCROLL SZO22 User Manual

Page 29

background image

23

2008SSD-34 (5/11)

22

2008SSD-34 (5/11)

Single-Compressor Module

Maintenance

5.2 Platform Symptoms Diagnosis

Use the following guidelines to troubleshoot operating problems.

Table 6

Platform troubleshooting guidelines

Problem

Recommended Actions

Low Gas

Flow

• Low inlet pressure
• Insufficient gas supply
• High temperature
• Bypass valve open
• Low Compressor speed
• Restricted inlet screen

High Oil

Carryover

• Saturated or dirty secondstage oil separator
• High oil level
• Restricted scavenge orifice
• Insufficient back pressure
• Oil dilution

Compressors

Won’t Run

• Determine drive status.
• Is inhibit circuit closed?
• Is run signal present?
• Does the VFD indicate a fault code?

Incorrect

Compressor

Speed

• Low inlet pressure
• High discharge pressure
• High temperature, fan, low oil, oil cooler
• Problem with speed control sensor and related components

High

Temperature

• Low oil level
• Restricted oil filter
• Blocked oil cooler air flow
• Oil cooler fan not operating
• Operation conditions outside of Compressor Module specifications