Appendix B: Cables
Twisted-Pair Cable and Pin Assignments
Caution:
DO NOT plug a normal phone jack connector into any RJ-45 port. Use only
twisted-pair cables with RJ-45 connectors that conform with FCC standards.
For 10/100BASE-TX connections, the twisted-pair cable must have two pairs of
wires. For 1000BASE-T connections the twisted-pair cable must have four pairs of
wires. Each wire pair is identified by two different colors. For example, one wire
might be green and the other, green with white stripes. Also, an RJ-45 connector
must be attached to both ends of the cable.
Caution:
Each wire pair must be attached to the RJ-45 connectors in a specific
orientation. (See “Cabling Guidelines” on page 4-2 for an explanation.)
Figure B-1 illustrates how the pins on the RJ-45 connector are numbered. Be sure to
hold the connectors in the same orientation when attaching the wires to the pins.
Figure B-1. RJ-45 Connector Pin Numbers
10/100BASE-TX Pin Assignments
Use unshielded twisted-pair (UTP) or shielded twisted-pair (STP) cable for RJ-45
connections: 100-ohm Category 3 or better cable for 10 Mbps connections, or
100-ohm Category 5 or better cable for 100 Mbps connections. Also be sure that the
length of any twisted-pair connection does not exceed 100 meters (328 feet).
Data is delivered on the standard two wire pairs (pins 1, 2, 3, and 6), and PoE power
is supplied using the two previously spare pairs (pins 4, 5, 7, and 8). Since the RJ-45
ports on the switch base unit support automatic MDI/MDI-X operation, you can use
straight-through cables for all network connections to PCs or servers, or to other
switches or hubs. In straight-through cable, pins 1, 2, 3, and 6, at one end of the
cable, are connected straight through to pins 1, 2, 3, and 6 at the other end of the
cable. When using any RJ-45 port on this switch, you can use either straight-through
or crossover cable.