Flat-PLU department link/tax status/listing capacity programming procedure
Step 1. Press
°
and
Step 2. Select “3.Key Feature” and press
`
, then select “1.PLU” and press
`
.
Step 1. screen
Step 2. screen
Step 3. Select the PLU record you want to program by pressing the flat-PLU key directly, by entering PLU record
No. and
`
, or by entering record No./random PLU code and
+
.
Step 4. Link department programming:
Select “Dept Link” line, press
`
, select the appropriate link department and
`
.
Tax status programming:
Select “Taxable status” line, and press
`
select the appropriate tax status.
Listing capacity programming:
Select “High Amount Limit” line (press
w
three times), and enter the amount and press
`
.
Step 3. screen
Step 4-1. screen
Step 4-2. screen
Step 4-3. screen
Step 5. Press
\
and repeat the step 3. and 4., if you program to the other record.
Step 6. Press
\
repeatedly to return to the “Step 1. screen”.
P3 C01 31-10-04 09:21 AM 000123
PGM-3
1.Machine Feature
2.Clerk
3.Key Feature
0.00
Key Feature
Key Feature
1.PLU
2.PLU 2nd@
3.Sub-Deparment
4.Department
5.Range
6.Individual PGM
7.Function Key
8.Shift PLU
´
0.00
Key Feature
PLU
1.PLU001
2.PLU002
3.PLU003
4.PLU004
5.PLU005
6.PLU006
7.PLU007
8.PLU008
´
0.00
Memory No. 1
Random Code 1
Descriptor PLU001
Price 10.00
Receipt type Normal Item
Item type Normal Item
Group Link --------
Dept Link
--------
Sub-Dept Link --------
Taxable status Non Tax
Commission None
Selective Item None
´
0.00
Memory No. 1
List Link #4 --------
¨
Open PLU NO
Zero Unit Price NO
Negative Price NO
Hash Item NO
Full Hash Item NO
High Amount Limit
0.00
Low Digit Limit 0
Multiple VLD N Repeat
Use main Item Amt Only NO
Use Premium Item of Set NO
0.00
Memory No. 1
Random Code 1
Descriptor PLU001
Price 10.00
Receipt type Normal Item
Item type Normal Item
Group Link --------
Dept Link --------
Sub-Dept Link --------
Taxable status
Non Tax
Commission None
Selective Item None
´
0.00