beautypg.com

Chapter 3: commands and programming – Casio EA-100 Commands and Programming User Manual

Page 33

background image

55

Chapter 3: Commands and Programming

4

Channel 4 (SONIC)

5

DIG IN channel

Operation Parameter

This parameter specifies the sampling unit for the Multimeter Mode.

The following are the available operation parameter settings whenever Channel
1 (CH1), Channel 2 (CH2), or Channel 3 (CH3) is specified by the channel
select parameter.

1

Auto-ID

If Auto-ID is not activated, voltage in the range 0 to 5V is used.

2

Voltage (

±

10V)

3

Current (

±

10A)

4

Resistance value (1k

to 100k

)

5

Period (0.000004 to 50 seconds)

6

Frequency (0.02Hz to 250kHz)

The following are the available operation parameter settings whenever SONIC
is specified by the channel select parameter.

1

Auto-ID

2

Meters

3

Feet

MULTIMETER MODE SETUP Example

The following example takes a single data sample on Channel 1.

{6,1,1,3}

6 = MULTIMETER MODE SETUP
1 = Enters Multimeter Mode
1 = Channel 1
3 = Current measurement