beautypg.com

Chapter 3: commands and programming – Casio EA-100 Commands and Programming User Manual

Page 16

background image

38

Chapter 3: Commands and Programming

1

Auto-ID

If Auto-ID is not activated, voltage in the range 0 to 5V is used.

2

Voltage (

±

10V)

3

Current (

±

10A)

Based on Vin input, 1V = 1A.

4

Resistance (1k

to 100k

)

5

Period (0.000004 to 50 seconds)

See “Period and Frequency Measurement” in Appendix A.

6

Frequency (0.02Hz to 250kHz)

See “Period and Frequency Measurement” in Appendix A.

7

Temperature (–20

°

C to 130

°

C)

8

Temperature (–4

°

F to 266

°

F)

9

Light (100 to 999)

10

Voltage (0 to 5V)

Post-Processing Parameter

This parameter specifies the type of post-processing to be applied to sam-
pled data. The initial default for this parameter is 0.

0

None (no processing)

1

d/dt

(first derivative)

Only the

d/dt

indicator is on the display when this type of post-

processing is selected.

2

d/dt

and

d

2

/dt

2

(first derivative and second derivative)

The

d/dt

and

d

2

/dt

2

indicators are on the display when this type

of post-processing is selected.

3

Statistics (mean, standard deviation, minimum, maximum)

Derivative and statistical post-processing are performed using values pro-
duced by conversion equations.

• Post-processing is disabled whenever the number of samples parameter

of Command 3 (SAMPLING/TRIGGER SETUP) is –1, which specifies
real-time display of sampled data.

Stat Samples Parameter

This parameter is used during statistical post-processing to specify how many
samples should be used for post-processing. This parameter is valid only
when 3 (statistics) is specified for the post-processing parameter. A value
from 2 to 512 can be specified for this parameter, and The initial default for
this parameter is 10.

P.68