beautypg.com

0 installation – Magnum Energy MM-R Remote User Manual

Page 6

background image

©

2010 Magnum Energy, Inc.

2

2.0 Installation

Before installing, read

the entire Installation section to determine

how you are going to install your remote control. The more thor-

ough you plan in the beginning, the better your inverter needs will

be met.

Pre-installation

• Carefully remove the MM-R or MM-RC remote from its shipping

container and inspect all contents. Verify the following items are

included:

− The correct MM remote control (MM-R or MM-RC)

− Mounting ring (used for surface mounting)

− 25’ communication cable (RJ11 connectors on each end)

− Two #6 Phillips head screws (to secure the display panel)

− MM-R/MM-RC Remote Owner’s Manual

• D

etermine a suitable location to mount the remote control. It

must be located in a clean, dry, and protected place.

• P

lan the cable route from the remote to the inverter before you

do any cutting or drilling to ensure there are no obstructions that

can’t be overcome.

• Allow ample room to access the ON/OFF switch, view the LEDs

for the inverter’s operational status and for any troubleshooting.

Connecting the Communications Cable

The communications cable is a 25’, 4-conductor cable (wired like a

normal telephone-type cable). This cable is connected to the RJ11

jack on the rear of the remote display panel and to the REMOTE

port located on the front of the inverter.

Info: The 25’ cable should be long enough for most

applications. If additional cable length is needed, the

cable can be extended up to 50 feet using a standard

phone cable and a female-to-female connector.

F ront S ide of

M M S eries Inverter

R E M OT E port

(R J11 connection)

R J11 connection

(located on the

rear of the rem ote )

C om m unications

cable (25')

Figure 2, Communications Cable Connections