beautypg.com

Magnum Energy MM-R Remote User Manual

Page 14

background image

©

2010 Magnum Energy, Inc.

10

BULK (yellow) -
• On (solid) – Bulk Charging; the charger is delivering maximum

current to the batteries. The charger will remain in Bulk Charge

until 14.6 VDC* is achieved (per Battery Type selection**).
• Blinks On (1 time every 4 seconds) – Charger Back-off; charger

current is reduced. This occurs if: 1. The internal temperature is

very hot (charger reduces charge rate to maintain temperature) or,

2. The AC input voltage has fallen below 85 VAC (charger reduces

charge rate to help stabilize the incoming AC voltage).

• Off –

charger is not in Bulk Charge mode.

ABSORB (yellow) -
• On (solid) – Absorb Charging; the charger is in constant voltage

stage and begins after the bulk voltage has been reached. The

DC charging current will start to taper down to maintain the bulk

voltage setting. The absorb charging time is 120 minutes (per

Battery AmpHrs selection**).
• Blinks On (1 time every 4 seconds) – Charger Back-off; charger

current is reduced. This occurs if: 1. The internal temperature is

very hot (charger reduces charge rate to maintain temperature) or,

2. The AC input voltage has fallen below 85 VAC (charger reduces

charge rate to help stabilize the incoming AC voltage).
• Off – charger is not in Absorption Charge mode.
FLOAT (green) -
• On (solid) – Float Charging; at the end of the absorb charging

time, the charger reduces the charge voltage to maintain the

batteries at 13.4* VDC (per Battery Type selection**).
• Blinks On (1 time every 4 seconds) – Charger Back-off; charger

current is reduced. This occurs if: 1. The internal temperature is

very hot (charger reduces charge rate to maintain temperature) or,

2. The AC input voltage has fallen below 85 VAC (charger reduces

charge rate to help stabilize the incoming AC voltage).
• Blinks On (2 times every 4 seconds) – Full Charge; monitors

the battery voltage to determine when to continue charging. After

four hours in the Float Charge mode, charger turns off and goes

to Full Charge mode. If the battery voltage drops to 12.9 VDC, the

charger will automatically initiate another fl oat charge.
• Off – charger is not in Float Charge mode.
* These voltage settings are based on the BTS being disconnected;

if connected, these voltage settings will increase or decrease

depending on temperature around the BTS – this ensures correct

charging.
** These settings are preset by the inverter or the connected

remote (see Table 1, Inverter and Remote Settings), but can be

changed by the ME-RC50 remote.

3.0 Operation

This manual is related to the following products: