CONFIGURATION

LBI-39076B

33

Who Has What Dedicated Line

Dedicated Line - This 3-digit field defines (for each
logical unit ID) the line number to be dedicated to
outgoing interconnect calls. Default is line 1. Enter a
line number, or 0 for denial. It is recommended that
you enter 0 for denial, and use unique rotary hunt
sequences to define dedicated lines.

Logical Unit Definition (menu selection 11)
Radio Parameters (panel 2)
Interconnect

Dedicated To Unit - This column of parameters defines
(for the site) the logical unit ID to which each line is
dedicated. Default is no logical unit ID (0) for all lines.
Enter a logical unit ID, or leave 0 for no logical unit ID.
It is recommended that you leave 0 for no logical unit
ID, and use unique rotary hunt sequences to define
dedicated lines.

Line Definition (menu selection 14)
Line Parameters (pages 1 & 2)

It is recommended that all dedicated line
assignments be set up by using the Rotary
Number
and Interconnect Rotary Definition
parameters, not the Dedicated Line parameter.
Set the Dedicated Line parameter to none (0),
and assign a unique Rotary Number and a
single unique line number in the corresponding
Interconnect Rotary Definition for each logical
unit ID requiring a dedicated line.

RECOMMENDATION

Existing telephone interconnect systems that currently

have dedicated lines defined by using non-zero values for
the Dedicated Line and Dedicated To Unit parameters, can
continue to use this method with the ELI system. However,
because the lines are typically numbered differently for the
ELI system, some reconfiguring of the line numbers will
probably be necessary. If you find this to be the case, you
may want to change to the recommended method at this
time, as described above.

GTI DATABASE

Some user-configurable parameters for the ELI system

reside in the active configuration of the GTI database, in
each GTI unit. The GTI database is configured with the

GTI Configurator software, using an office PC connected
through a data link to one GTI unit. The re-configured GTI
database will be cloned to each other GTI unit that is
connected to this one GTI unit.

Local Data Link

Using a local data link between an office PC and one

GTI unit, requires less equipment and is less complicated to
set up than a remote data link. A local data link should not
exceed 50 feet in length and requires the following four
items:

1. PC-Based Terminal (Not Supplied) - The customer

must supply a PC-based terminal with the following
features:

IBM-compatible 386 or better

MS-DOS version 3.2 minimum operating system

10 MB available hard drive

640 KB minimum RAM (recommend 2 MB)

1.2 MB 5.25-inch or 1.44 MB 3.5-inch floppy
drive

Monochrome or color monitor

Available male 9-pin RS-232 port (If a male 9-pin
serial port is not available, an adapter will be
required.)

2. RS-232 Data Cable (Supplied) - A 10-foot

19D903985P72 cable is supplied with male and female
9-pin connectors.

3. GTI Configurator Software (Supplied) - The GTI

Configurator software is supplied in both 3.5 and 5.25-
inch floppy formats.

4. GTI Configurator User’s Guide (Supplied)

Figure 41 shows how an office PC with a 9-pin COM

port is connected to a GTI unit. Figure 42 shows how an
office PC with a 25-pin COM port is connected to a GTI
unit.