beautypg.com

Iam connections – Ericsson LBI-39076B User Manual

Page 27

background image

INSTALLATION

LBI-39076B

27

2#56022

601-0537

(C) ZETRON INC.

U23

IAM

V1.2

Software Version #

Circuit Symbol

Figure 35 - IAM Software Label

12. IAM CONNECTIONS

The 12th step needed to install the ELI option applies

only if an IAM was supplied. All connections to the IAM
are made to connectors on the rear panel, as shown in Figure
36.

PCM / Data

Bus

Power Supply

Printer

RS-232 Port

PRINTER

P2

ALARM

Outputs

Alarm

POWER

(P1)

(J2)

(P2)

(J3)

Figure 36 - IAM Rear Panel Connections

Power Supply

Connect a 19B803968P1 cable from the male 1x6-pin

Molex connector on the back of the IAM (marked
"POWER") to P801 on the repeater power supply, as shown
in Figure 37. Note that the power supply end of the cable
comes with pins attached to the wires, but no connector
shell. These pins are to be inserted into the existing
connector shell already connected to P801 on the power
supply.

IAM

Power Supply

3

*

P801

6

5

19B803968P1 Cable

POWER

Gnd

+12 Vdc

Neg

Pos

Existing Connector

Red

Black

* 5 for MASTR II and IIe

6 for MASTR III

Figure 37 - IAM Power Supply Connections

For a power supply connected to a MASTR III repeater,

insert the pin on the red wire into pin position 3 and the pin
on the black wire into pin position 6.

For a power supply connected to a MASTR II or IIe

repeater, remove the existing pins in pin positions 3 and 5,
and tie back. Then insert the pin on the red wire into pin
position 3 and the pin on the black wire into pin position 5.

PCM/Data Bus

Connect the PCM/Data bus cables as instructed in the

previous section for the GTI units.

Alarm Outputs

The IAM provides three open-drain alarm outputs for

the user to connect to an alarm system, if desired. These
alarm outputs will go through indeterminate states during
IAM power-up or reset. If the Active High output
configuration is selected by setting DIP switch section 7 to
the up position, all alarms will be active if the IAM loses
power. Conversely, if the Active Low output configuration
is selected by setting DIP switch section 7 to the down
position, no alarms will be active if the IAM loses power.
The standard ELI option does not provide a cable for this
connection, but pin-out information is shown in Figure 38.
Pins 7 through 10 are not used.

1

2

3

4

5

6

7

8

9

10

Pin

Alarm

Function

1
2
3
4
5

Ground

Ground

Ground

Ground

Ground

Alarm 1

Alarm 2

Alarm 3

Alarm 4

Alarm 5

SMDR Full or Memory Error

6
7
8
9

10

Bus Failure

Low Battery

Not Used

Not Used

ALARM OUTPUTS CONNECTOR

Figure 38 - IAM Alarm Outputs

Printer RS-232 Port

A female 9-pin RS-232 serial printer port, labeled

“PRINTER”, is provided in the rear panel of the IAM
allowing you to connect a printer to keep real-time records
of calls being placed on your system (a record is printed
after each call ends). The proper baud rate for the port can