beautypg.com

Terminal am/fm signal selection, Memobus/modbus termination, I.3 electrical installation safety – Yaskawa CIMR-PU User Manual

Page 43

background image

The PTC must exhibit the characteristics shown in

Figure i.21

in one motor phase. The motor overload protection of the drive

expects 3 of these PTCs to be connected in a series.

Resistance ( )

Class F
150 ºC

Class H
180 ºC

Tr: threshold value

Temperature

Tr’

Tr + 5K (oH4 Fault Level)

Tr

Tr - 5K (oH3 Alarm Level)

Figure i.21 Motor PTC Characteristics

Set up overheat detection using a PTC using parameters L1-03, L1-04, and L1-05 as explained in the following sections.

u

Terminal AM/FM Signal Selection

The signal type for terminals AM and FM can be set to either voltage or current output using jumper S5 on the terminal board

as explained in

Table i.16

. When changing the setting of jumper S5, parameters H4-07 and H4-08 must be set accordingly.

The default selection is voltage output for both terminals.

Table i.16 Jumper S5 Settings

Terminal

Voltage Output

Current Output

Terminal AM

AM

FM

V

I

AM

FM

V

I

Terminal FM

AM

FM

V

I

AM

FM

V

I

Table i.17 Parameter H4-07 and H4-08 Details

No.

Parameter Name

Description

Setting

Range

Default

Setting

H4-07

Terminal AM signal level selection

0: 0 to 10 Vdc

1: -10 to 10 Vdc

2: 4 to 20 mA

0 to 2

0

H4-08

Terminal FM signal level selection

u

MEMOBUS/Modbus Termination

This drive is equipped with a built-in termination resistor for the RS-422/485 communication port. DIP switch S2 enables or

disabled the termination resistor as shown in

Table i.18

. The OFF position is the default. The termination resistor should be

placed to the ON position when the drive is the last in a series of slave drives.

Refer to Switches and Jumpers on the Terminal

Board on page 40

to locate switch S2.

Table i.18 MEMOBUS/Modbus Switch Settings

S2 Position

Description

ON

Internal termination resistor ON

OFF

Internal termination resistor OFF (default setting)