Instructions on Installation Using the Eye Bolts

Eye bolts are used to install the drive or to temporarily lift the drive when replacing it. Using the eye bolts, the drive can be

installed in an enclosure panel or on a wall. Do not leave the drive suspended by the wires in a horizontal or vertical position

for long periods of time. Do not transport the drive over long distances. Read the following precautions and instructions before

installing the drive.

WARNING!

Crush Hazard. Observe the following instructions and precautions. Failure to comply could result in serious injury or death from

falling equipment.

Only use vertical suspension to temporarily lift the drive during installation to an enclosure panel. Do not use vertical suspension to transport

the drive.

Use screws to securely affix the drive front cover, terminal blocks, and other drive components prior to vertical suspension.

Do not subject the drive to vibration or impact greater than 1.96 m/s

2

(0.2 G) while it is suspended by the wires.

Do not leave the drive unattended while it is suspended by the wires.

Do not attempt to flip the drive over while it is suspended by the wires.

n

Horizontal Suspension of Drive Models 2A0360, 2A0415, and 4A0250 to 4A0675

To make a wire hanger or frame for use when lifting the drive with a crane, lay the drive in a horizontal position and pass a

wire through the holes of the four eye bolts.

NOTICE:

Damage to Equipment. When lifting the drive, confirm that the spring washer is fully closed. Failure to comply may deform or

damage the drive when lifted.

Figure 2.7

B

A

C

D

A – No space between drive and washer

B – Spring washer fully closed

C – Space between drive and washer

D – Spring washer open

Figure i.1 Spring Washer

n

Vertical Suspension of Drive Models 2A0360, 2A0415, and 4A0250 to 4A1200

Models 2A0360, 2A0415, and 4A0250 to 4A0675

When vertical suspension of the drive is required in an enclosure panel, change the orientation of the eye bolts for these models

by turning the eye bolts counterclockwise 90 degrees.

Figure i.2 Adjusting Angle of Eye Bolts

Models 4A0930 and 4A1200

When suspending models 4A0930 or 4A1200 with wires, follow the procedure described below.

i.2 Mechanical Installation Safety