n

Three-Phase 600 V Class

Table i.7 Wire Gauge and Torque Specifications (Three-Phase 600 V Class)

Drive Model

Terminal

Recomm. Gauge

AWG, kcmil

Wire Range

AWG, kcmil

Screw

Size

Tightening Torque

N·m (lb.in.)

5A0003
5A0004
5A0006

R/L1, S/L2, T/L3

14

14 to 10

M4

1.2 to 1.5

(10.6 to 13.3)

U/T1, V/T2, W/T3

14

14 to 10

⊖, ⊕1, ⊕2

14 to 10

B1, B2

14 to 10

10

14 to 10

5A0009

R/L1, S/L2, T/L3

14

14 to 10

M4

1.2 to 1.5

(10.6 to 13.3)

U/T1, V/T2, W/T3

14

14 to 10

⊖, ⊕1, ⊕2

14 to 10

B1, B2

14 to 10

10

12 to 10

5A0011

R/L1, S/L2, T/L3

10

14 to 6

M4

2.1 to 2.3

(18.6 to 20.4)

U/T1, V/T2, W/T3

14

14 to 6

⊖, ⊕1, ⊕2

14 to 6

B1, B2

14 to 10

8

12 to 8

M5

2.0 to 2.5

(17.7 to 22.1)

5A0017

R/L1, S/L2, T/L3

10

10 to 6

M5

3.6 to 4.0

(31.8 to 35.4)

U/T1, V/T2, W/T3

10

10 to 6

⊖, ⊕1, ⊕2

10 to 6

B1, B2

10 to 8

2.7 to 3.0

(23.9 to 26.6)

8

12 to 8

M6

5.4 to 6.0

(47.8 to 53.1)

5A0022

R/L1, S/L2, T/L3

8

10 to 6

M5

3.6 to 4.0

(31.8 to 35.4)

U/T1, V/T2, W/T3

10

10 to 6

⊖, ⊕1, ⊕2

10 to 6

B1, B2

10 to 8

2.7 to 3.0

(23.9 to 26.6)

8

10 to 6

M6

5.4 to 6.0

(47.8 to 53.1)

5A0027
5A0032

R/L1, S/L2, T/L3

6

6 to 4

M6

5.4 to 6.0

(47.8 to 53.1)

U/T1, V/T2, W/T3

6

6 to 4

⊖, ⊕1, ⊕2

6 to 4

B1, B2

10 to 8

M5

2.7 to 3.0

(23.9 to 26.6)

6

10 to 6

M6

5.4 to 6.0

(47.8 to 53.1)

5A0041

R/L1, S/L2, T/L3

6

10 to 3

M8

9.0 to 11

(79.7 to 97.4)

U/T1, V/T2, W/T3

6

10 to 3

⊖, ⊕1

6 to 1

B1, B2

12 to 3

6

6

5A0052

R/L1, S/L2, T/L3

4

10 to 3

M8

9.0 to 11

(79.7 to 97.4)

U/T1, V/T2, W/T3

6

10 to 3

⊖, ⊕1

6 to 1

B1, B2

8 to 3

6