beautypg.com

Yaskawa VS606 V74X V7 to V1000 User Manual

Page 20

background image

Product Transition Guide

PL. V1000-4X.01 Rev: 6/22/10

PL.V1000-4X.01 Transition Guide 6/22/10
Page 20 of 32
Yaskawa America, Inc.

Analog output AM

function selection

n066

0

H4-01

102

V74X

V1000-4X

n066 0

H4-01 102

n066 1

H4-01 103

n066 2

H4-01 107

n066 3

H4-01 109

n066 4

H4-01 108

n066 5

H4-01 106

n066 6

H4-01 101

Analog output AM gain

n067

1.00

H4-02

100.0%

Analog frequency ref.

gain (Volt. input CN2)

Terminal A2 gain

n068

100%

H3-11

100.0%

H3-09 must be set to 0 or 1

Analog freq. reference
bias (Volt. input CN2)

Terminal A2 bias

n069

0%

H3-12

0.0%

Analog frequency ref.

filter (Volt. input CN2)

n070

0.10s

H3-13

0.03

Filter time H3-13 is the same for analog

input A1 and A2 in V1000-4X

Analog frequency ref.

gain (Cur. input CN2)

Terminal A2 gain

n071

100%

H3-11

100.0%

H3-09 must be set to 2 or 3

Analog frequency ref.

bias (Cur. input CN2)

Terminal A2 gain

n072

0%

H3-12

0.0%

Analog frequency ref.

filter (Volt. input CN2)

n073

0.10s

H3-13

0.03

Filter time H3-13 is the same for analog

input A1 and A2 in V1000-4X

Pulse input gain

n074

100%

H6-03

100.0%

Pulse input bias

n075

0%

H6-04

0.0%

Pulse input filter time

n076

0.10 sec

H6-05

0.10 sec

Analog input function

selection (CN2

Terminal A2)

n077

0

H3-10

0

n077 0

H3-10 F

n077 1

H3-10 2

n077 2

H3-10 1

n077 3

H3-10 0

n077 4

H3-10 4

Analog input signal level

selection (CN2

Terminal A2)

n078

0

H3-09

1

n078 0

H3-09 0

n078 1

H3-09 2

Frequency reference bias

max. value for terminal
CN2 reference input

terminal A2

n079

10%

-

-

This function can not be used with

current input in the V1000-4X.

For voltage input at terminal A2 the

following has to be set:

H3-09 1
H3-10 0

H3-11 n079

H3-11 -n079

Drive

Parameter

Function

V74X

V1000-4X

Note

Param.

No.

Initial

Value

Set

Value

Param.

No.

Initial

Value

Set

Value