Yaskawa VS606 V74X V7 to V1000 User Manual
Page 17

PL.V1000-4X.01 Transition Guide 6/22/10
Page 17 of 32
Yaskawa America, Inc.
Product Transition Guide
PL. V1000-4X.01 Rev: 6/22/10
Deceleration time 2
n022
10.0
sec
C1-04
10.0
sec
S-curve at accel. Start
n023
0 (0 sec)
C2-01
0.2 sec
In the V74X one of four values could be
selected for all s-curves. The V1000-4X
requires a separate time setting for each
s-curve.
S-curve at accel. End
n023
0 (0 sec)
C2-02
0.2 sec
S-curve at decel. start
n023
0 (0 sec)
C2-03
0.2 sec
S-curve at decel. end
n023
0 (0 sec)
C2-04
0.2 sec
Multi speed reference 1
n024
6.00 Hz
d1-01
o2-09,
FMAX
dep.
Multi speed reference 2
n025
0.00 Hz
d1-02
0 Hz
Multi speed reference 3
n026
0.00 Hz
d1-03
0 Hz
Multi speed reference 4
n027
0.00 Hz
d1-04
0 Hz
Multi speed reference 5
n028
0.00 Hz
d1-05
0 Hz
Multi speed reference 6
n029
0.00 Hz
d1-06
0 Hz
Multi speed reference 7
n030
0.00 Hz
d1-07
0 Hz
Multi speed reference 8
n031
0.00 Hz
d1-08
0 Hz
Jog frequency
n032
6.00 Hz
d1-17
6.00 Hz
Frequency reference
upper limit
n033
100%
d2-01
100.0%
Frequency reference
lower limit
n034
0%
d2-02
0.0%
Digital operator display
unit for frequency
reference values.
n035
0
o1-03
0
V74X
V1000-4X
n035 0
o1-03 0
n035 1
o1-03 1
n035 2~39
o1-03 2 and set
E2-04, E4-04,
E4-05
n035 40~3999
o1-03 3 and set
o1-10, o1-11
Motor rated current
n036
E2-01
kVA
dep.
Depends on the drive capacity
(V74X ,V1000-4X)
Motor overload
protection
n037
0
L1-01
1
n037 0
L1-01 1
n037 1
L1-01 2~4
n037 2
L1-01 0
Motor overload
protection time
n038
8 min
L1-02
1 min
Needs not to be changed.
Drive cooling fan
operation selection
n039
0
L8-10
0
n039 0
ÁÂÃÄÅ Å
n039 1
L8-10 1
Phase order selection
n040
0
b1-14
0
n040 0
b1-14 0
n040 1
b1-14 1
Acceleration Time 3
n041
10 sec
C1-05
10.0 sec
In V1000-4X also used as Accel Time 1
for Motor 2
Deceleration Time 3
n042
10 sec
C1-06
10.0 sec
In V1000-4X also used as Decel Time 1
for Motor 2
Acceleration Time 4
n043
10 sec
C1-07
10.0 sec
In V1000-4X also used as Accel Time 2
for Motor 2
Deceleration Time 4
n044
10 sec
C1-08
10.0 sec
In V1000-4X also used as Decel Time 2
for Motor 2
Drive
Parameter
Function
V74X
V1000-4X
Note
Param.
No.
Initial
Value
Set
Value
Param.
No.
Initial
Value
Set
Value