PL. V1000-4X.01 Rev: 6/22/10
PL.V1000-4X.01 Transition Guide 6/22/10
Page 18 of 32
Yaskawa America, Inc.
Frequency reference bias
step value (up/down2)
n045
0.0 Hz
d4-03
0.0 Hz
Frequency reference bias
accel/decel rate
(up/down2)
n046
0
d4-04
0
V74X
V1000-4X
n046 0
d1-04 0 (use
current Accel /
decel time)
n046 1
d1-04 1 (use
Accel/decel time 4)
Frequency reference bias
operation mode selection
(up/down2)
n047
0
d4-05
0
Frequency reference bias
value (up/down2)
n048
0.0%
d4-06
0.0%
Analog frequency
reference fluctuation
limit (up/down2)
n049
1.0%
d4-07
1.0%
Terminal S1 function
selection
n050
1
H1-01
40
n050~56 1
H1-01~H1-06 40
n050~56 2
H1-01~H1-06 41
n050~56 3
H1-01~H1-06 24
n050~56 4
H1-01~H1-06 25
Terminal S2 function
selection
n051
2
H1-02
41
n050~56 5
H1-01~H1-06 14
n050~56 6
H1-01~H1-06 3
n050~56 7
H1-01~H1-06 4
n050~56 8
H1-01~H1-06
n050~56 9
H1-01~H1-06 32
Terminal S3 function
selection
n052
3
H1-03
24
n050~56 10
H1-01~H1-06 6
n050~56 11
H1-01~H1-06 7
n050~56 12
H1-01~H1-06 8
n050~56 13
H1-01~H1-06 9
n050~56 14
H1-01~H1-06 61
Terminal S4 function
selection
n053
5
H1-04
14
n050~56 15
H1-01~H1-06 62
n050~56 16
H1-01~H1-06 A
n050~56 17
H1-01~H1-06 1
n050~56 18
H1-01~H1-06 2
and b1-15 2
and b1-16 2
n050~56 19
H1-01~H1-06 28
Terminal S5 function
selection
n054
6
H1-05
3
(0)
n050~56 20
H1-01~H1-06 2C
n050~56 21
H1-01~H1-06 29
n050~56 22
H1-01~H1-06 2F
n050~56 23
H1-01~H1-06 19
n050~56 24
H1-01~H1-06 30
Drive
Parameter
Function
V74X
V1000-4X
Note
Param.
No.
Initial
Value
Set
Value
Param.
No.
Initial
Value
Set
Value