beautypg.com

Yaskawa J7 to J1000 User Manual

Page 9

background image

(Header Title) Application Note


Doc#: PL.J1000.01 Copyright Yaskawa Electric America, Inc.©2008 www.yaskawa.com August 1, 2008 9 of 19

Subject: Transition Guide

Product: J1000

Document: PL.J1000.01

Title: Product Transition Guide – J7 to J1000

Product Transition Guide – J7 to J1000

„

4.5 Control Terminal and Wire Sizes

Voltage

Class

Drive

Terminal Symbol

Screw

Size

Tightening

Torque

N.m

(lb - in.)

Wire Size

mm

2

(AWG)

Recommended

Wire Size

mm

2

(AWG)

J7

S1 - S5, SC, FS, FR,

FC, AM, AC

Flexible: 0.5 ~ 0.75

(20 to 18)

Solid: 0.5 ~ 1.25

(20 to 18)

J1000

S1 - S5, SC, V+, A1,

AC, AM, AC

M2

0.22 ~ 0.25

(1.9 to 2.2)

Flexible: 0.25 ~ 1.0

(24 to 18)

Solid: 0.25 ~ 1.5

(24 to 16)

0.75

(18)

J7

Flexible: 0.5 ~ 0.75

(20 to 18)

Solid: 0.5 ~ 1.25

(20 to 18)

All

J1000

MA, MB, MC

M3

0.5 ~ 0.6

(4.4 to 5.3)

Flexible: 0.25 ~ 1.0

(24 to 18)

Solid: 0.25 ~ 1.5

(24 to 16)

0.75

(18)