(Header Title) Application Note
Doc#: PL.J1000.01 Copyright Yaskawa Electric America, Inc.©2008 www.yaskawa.com August 1, 2008 17 of 19
Subject: Transition Guide
Product: J1000
Document: PL.J1000.01
Title: Product Transition Guide – J7 to J1000
Product Transition Guide – J7 to J1000
J7
J1000
Drive
Function
/ Parameter
Parameter
No.
Initial
Value
Parameter
No.
Initial
Value
Comments
Over Torque Detection
Level
n60 160%
L6-02 150%
—
Over Torque Detection
Time
n61
0.1 s
L6-03
0.1 s
—
Frequency Reference
Hole Selection
(Up / Down Function)
n62 0
d4-01 0
J7 J1000
n62 Æ 0
d4-01 Æ 0
n62 Æ 1
d4-01 Æ 1
Torque Compensation
Gain
n63 1.0
C4-01
1.00
—
Motor Rated Slip
n64
—
E2-02
—
Default value depends on the drive capacity.
Motor No-Load Current
n65 —
E2-03 —
Default value depends on the drive capacity.
Set E2-03 = n32* n65 / 100%
Slip Compensation Gain
n66 0.0
C3-01 0.0
—
Slip Compensation
Time Constant
n67
2.0 s
C3-02
2000 ms
J7: Setting unit is 1.0 s
J1000: Setting unit is 1 ms
MEMOBUS / Modbus
Communication Error
Behavior Selection
n68 0
H5-04
H5-05
3 —
MEMOBUS / Modbus
Communication Error
Detection
— —
H5-05 1
J1000
J7
H5-04 H5-05
n68 Æ 0
1
n68 Æ 1
0 (C1-02)
n68 Æ 2
2 (C1-09)
n68 Æ 3
3
1
n68 Æ 4
No effect
0
MEMOBUS / Modbus
Frequency Reference
and Monitor Units
n69 0
H5-13 0
J7 J1000
n69 Æ 0
H5-13 Æ 0
n69 Æ 1
H5-13 Æ 1 and
o1-03 Æ 0
n69 Æ 2
H5-13 Æ 2
n69 Æ 3
H5-13 Æ 3
MEMOBUS / Modbus
Slave Address
n70 0
H5-01
1F
J7: Set as decimal value.
J1000: Set as hexadecimal value.
MEMOBUS / Modbus
Communication Speed
Selection
n71 2
H5-02 3
J7 J1000
n71 Æ 0
H5-02 Æ 1
n71 Æ 1
H5-02 Æ 2
n71 Æ 2
H5-02 Æ 3
n71 Æ 3
H5-02 Æ 4
MEMOBUS / Modbus
Parity Selection
n72 0
H5-03 0
J7 J1000
n72 Æ 0
H5-03 Æ 1
n72 Æ 1
H5-03 Æ 2
n72 Æ 2
H5-03 Æ 0
Transmission Wait Time
n73
10 ms
H5-06
10 ms
—